Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1989-01-04 12:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.511164, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1989-01-04T12:00:00 * Date/Time End: 1989-01-04T12:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 21816 m
Event(s):
GF_9030 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1989-01-04T12:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 7020 m
Size:
364 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130975.00.0808.03.1
338950.00.0838.93.1
771900.00.08810.83.2
878888.00.08911.33.3
1023872.0-3.19012.03.3
1223850.0-7.59012.13.3
1398831.0-11.39012.23.4
1688800.0-13.19012.43.5
1959772.0-14.99012.63.5
2661703.0-19.39013.03.6
2693700.0-19.59012.83.6
3445632.0-24.3767.63.8
3822600.0-27.2605.43.8
3906593.0-27.9555.03.8
3991586.0-28.6565.03.8
4650534.0-33.7655.03.6
5053504.0-36.9496.53.4
5108500.0-37.0476.73.4
5362482.0-37.7417.83.3
5405479.0-38.0408.03.3
6173428.0-42.63510.03.0
6627400.0-45.3328.82.9
6728394.0-45.9328.62.8
6950381.0-47.3308.03.2
7020377.0-47.7287.33.3
7666342.0-45.83153.04.4
7864332.0-45.22873.84.7
8302311.0-43.92607.04.8
8544300.0-43.22517.34.8
8890285.0-42.22408.04.9
9257270.0-41.12489.55.0
9384265.0-40.825010.05.2
9410264.0-40.725010.05.2
9781250.0-40.82469.75.6
10144237.0-40.82429.46.0
10498225.0-40.92389.36.0
10776216.0-41.02359.16.0
11299200.0-41.12289.06.4
11977181.0-41.22209.07.0
12206175.0-41.32239.47.2
12324172.0-41.32249.77.3
12815160.0-41.422910.78.1
12943157.0-41.423011.08.1
13253150.0-41.522610.98.2
13843137.5-41.621910.88.3
14382127.0-41.721210.98.4
14490125.0-41.621111.08.4
14544124.0-41.621011.08.5
15175113.0-41.11807.09.8
15205112.5-41.01817.19.9
15297111.0-41.01847.410.1
15675105.0-40.71959.010.7
16007100.0-40.41937.911.2
1659991.7-39.91896.112.0
1672790.0-39.81885.712.4
1695187.1-39.61855.013.0
1753380.0-39.21634.914.6
1761979.0-39.11605.014.8
1763678.8-39.11615.014.9
1821872.4-38.61935.914.5
1826671.9-38.61956.014.5
1845070.0-38.41865.514.6
1887565.8-38.11605.014.9
1896065.0-38.01625.015.0
1950060.1-37.61755.015.4
1951260.0-37.61755.015.4
1983057.3-37.31664.615.4
2011355.0-36.11574.415.4
2037153.0-35.01484.315.4
2077950.0-33.31334.416.0
2138445.9-30.71155.016.8
2139945.8-30.716.9
2152445.0-30.116.4
2181643.2-28.915.5