Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1987-10-24 12:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.511085, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1987-10-24T12:00:00 * Date/Time End: 1987-10-24T12:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 28646 m
Event(s):
GF_8951 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1987-10-24T12:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 10124 m, total ozone 163.2 DU
Size:
492 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130958.0-11.3902.01.6
194950.0-11.11243.31.7
219947.0-11.01304.01.8
267941.0-10.91304.11.9
600901.0-12.81304.82.9
608900.0-12.81304.92.9
1042850.0-15.31305.82.6
1498800.0-17.91306.82.3
1573792.0-18.31307.02.3
1716777.0-19.11336.22.3
2290719.0-21.91573.02.3
2352713.0-21.71622.82.3
2424706.0-21.71702.52.3
2487700.0-21.71782.32.3
2529696.0-21.71852.22.3
3177637.0-25.42604.02.1
3609600.0-27.82675.32.0
3889577.0-29.42716.12.0
4775509.0-34.52778.91.8
4900500.0-35.22779.31.8
5658448.0-39.528011.71.8
5766441.0-40.128012.01.7
6427400.0-43.830514.91.4
6444399.0-43.930515.01.3
6930371.0-46.730516.41.1
7147359.0-48.430517.01.0
7202356.0-48.830617.00.9
8306300.0-57.232318.00.9
8874274.0-61.533119.00.9
9436250.0-65.833820.41.2
9559245.0-66.733920.71.2
9658241.0-67.134021.01.3
10071225.0-68.933720.21.4
10124223.0-69.133720.11.5
10371214.0-69.433519.71.6
10774200.0-69.933319.02.9
11237185.0-70.532918.24.5
11567175.0-70.932617.84.6
12247156.0-71.732016.94.7
12478150.0-72.031816.74.7
12990137.5-72.631316.24.6
13185133.0-72.931116.14.5
13319130.0-73.031016.04.3
13549125.0-73.330415.74.1
13936117.0-73.829515.63.6
14165112.5-74.128915.82.6
14349109.0-74.328516.01.8
14851100.0-74.228516.00.7
1498697.7-74.228516.00.4
1503496.9-74.228516.00.4
1546590.0-74.128118.10.2
1610180.7-74.027721.30.0
1615280.0-74.027721.60.1
1684071.1-73.927425.11.1
1693170.0-73.727325.61.3
1736665.0-72.527227.91.9
1742064.4-72.427228.22.0
1783860.0-71.327030.41.7
1835455.0-70.026933.21.3
1845254.1-69.726933.71.2
1892350.0-68.526836.22.8
1915648.1-67.926837.53.6
1947745.6-67.126739.22.4
1955745.0-66.926739.72.8
1969344.0-66.526740.43.6
1994742.2-65.126641.85.1
2027540.0-63.326643.53.1
2067437.5-61.126545.75.2
2077436.9-60.526546.35.8
2091136.1-59.826547.06.4
2110535.0-58.726546.97.3
2123234.3-58.426546.97.9
2157132.5-57.626546.87.6
2185031.1-57.026546.77.4
2207830.0-56.526546.77.5
2251728.0-55.526546.67.7
2260927.6-55.326546.57.7
2299126.0-54.426546.47.5
2324225.0-53.826546.47.4
2329424.8-53.726546.37.4
2345224.2-53.026546.37.3
2350524.0-52.726546.37.3
2407122.0-50.126546.17.6
2431321.2-49.026546.17.7
2450220.6-48.126546.07.6
2469720.0-47.226546.67.5
2503819.0-45.726547.67.3
2507318.9-45.526547.77.2
2539918.0-44.526548.77.0
2555017.6-44.026549.16.9
2578317.0-43.326549.86.9
2619316.0-42.126551.16.9
2658515.1-40.926552.26.9
2663115.0-40.826552.46.8
2710214.0-39.326553.86.5
2750613.2-38.126555.06.1
2761113.0-37.86.1
2777212.7-37.35.9
2816512.0-36.15.8
2864611.2-34.75.5