Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1987-10-12 12:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.511080, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1987-10-12T12:00:00 * Date/Time End: 1987-10-12T12:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 21749 m
Event(s):
GF_8946 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1987-10-12T12:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 14190 m
Size:
522 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130970.0-19.93551.00.7
284950.0-20.2781.91.0
379938.0-20.4903.01.2
619908.0-20.9906.71.7
684900.0-21.4907.71.8
701898.0-21.6908.01.9
858879.0-22.8906.01.8
1018860.0-24.11005.01.8
1103850.0-24.31064.61.8
1138846.0-24.31094.41.8
1242834.0-24.51204.01.8
1445811.0-24.92291.51.8
1508804.0-25.32552.61.8
1544800.0-25.62623.41.8
1572797.0-25.82654.01.8
1849767.0-27.92284.81.8
1877764.0-28.22255.01.7
2163734.0-30.42455.01.4
2280722.0-31.32465.11.3
2339716.0-31.52475.21.2
2428707.0-31.72485.31.1
2499700.0-31.92495.31.2
3064646.0-33.42556.01.8
3086644.0-33.52556.01.7
3535604.0-34.72417.51.4
3582600.0-34.82407.71.4
3605598.0-34.92407.81.4
3902573.0-36.42348.91.6
4160552.0-37.623010.01.4
4453529.0-39.123011.91.2
4584519.0-40.223012.81.1
4810502.0-42.123014.21.4
4837500.0-42.423014.41.3
4878497.0-42.723014.71.3
4973490.0-43.223015.31.1
5267469.0-44.923017.21.6
5737437.0-47.623020.31.1
5983421.0-49.023021.91.6
6156410.0-50.023023.01.4
6317400.0-50.923022.81.3
6499389.0-51.923022.51.1
7362340.0-56.823021.21.6
8024306.0-60.623020.20.7
8147300.0-61.323020.00.8
8399288.0-62.723019.61.1
8979262.0-65.023018.81.6
9144255.0-65.723018.52.1
9264250.0-66.223018.42.2
9436243.0-66.823018.12.3
9613236.0-67.623017.82.9
9899225.0-68.723017.43.0
10171215.0-69.823017.03.0
10199214.0-69.922916.83.0
10311210.0-69.922716.23.0
10602200.0-69.921914.73.4
10752195.0-69.921514.03.5
10783194.0-69.921613.93.6
11033186.0-70.722713.53.9
11394175.0-71.924413.93.9
11427174.0-72.024514.04.0
11530171.0-72.324313.64.0
11774164.0-74.523612.84.0
12029157.0-73.722912.24.0
12141154.0-73.922512.04.1
12256151.0-74.222811.74.1
12295150.0-74.322911.74.1
12655141.0-75.024011.13.9
12801137.5-75.324411.03.9
12822137.0-75.424511.03.9
13125130.0-76.024110.53.9
13351125.0-76.523810.23.4
13538121.0-76.923510.03.0
13781116.0-77.423610.13.3
13956112.5-77.823610.23.1
14190108.0-78.323710.32.9
14629100.0-78.323810.52.5
1480996.9-78.223810.62.3
1499493.8-78.223910.71.0
1515591.2-78.223910.80.4
1523190.0-78.223910.80.4
1556484.9-78.224011.00.0
1558484.6-78.224011.00.0
1590380.0-78.224711.10.0
1666670.0-78.126211.80.0
1683268.0-78.126512.00.0
1709065.0-78.126412.70.0
1740661.5-78.026313.60.0
1754760.0-78.026214.00.1
1793156.1-78.026115.10.4
1804555.0-78.026115.40.4
1824653.1-78.026016.00.4
1859050.0-77.927016.70.4
1894347.0-77.928018.00.4
1898046.7-77.928018.10.4
1919345.0-77.027918.40.4
1924444.6-76.727918.40.4
1963341.7-75.027819.01.4
1987540.0-74.027819.41.7
2008338.6-73.027719.71.9
2025337.5-72.327719.92.1
2066135.0-70.527620.52.6
2097533.2-69.127521.03.0
2110332.5-68.63.2
2136831.1-67.43.5
2158530.0-66.44.0
2174929.2-65.74.5