Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1987-01-05 00:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.511038, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1987-01-05T00:00:00 * Date/Time End: 1987-01-05T00:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 28641 m
Event(s):
GF_8904 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1987-01-05T00:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 8225 m
Size:
565 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130976.0-1.11257.01.4
345950.0-1.9987.51.4
404943.0-2.1927.91.4
420941.0-2.3908.01.4
772900.0-5.4958.71.4
1190853.0-9.11009.71.5
1217850.0-9.41009.81.5
1363834.0-10.710210.11.5
1682800.0-12.810510.91.5
1730795.0-13.110511.01.5
1788789.0-13.410411.51.5
2082759.0-15.310014.01.4
2582710.0-18.69911.91.2
2688700.0-19.39911.51.3
3698610.0-25.8947.31.5
3818600.0-26.6936.81.4
4237566.0-29.3885.11.2
4770525.0-32.8753.01.1
5112500.0-35.0553.11.1
5168496.0-35.3513.11.0
5994440.0-40.7194.61.7
6150430.0-41.7155.01.3
6261423.0-42.4145.11.0
6637400.0-44.6115.41.4
6704396.0-45.0105.41.5
6962381.0-46.585.61.0
7447354.0-49.356.01.3
8083321.0-53.106.91.7
8164317.0-53.53607.02.0
8225314.0-53.93596.92.2
8518300.0-52.93536.33.3
9082275.0-50.93395.45.4
9525257.0-49.43255.05.9
9706250.0-48.83244.96.1
10002239.0-47.83224.76.4
10142234.0-47.33214.66.0
10228231.0-47.23214.55.9
10402225.0-47.13204.46.1
10491222.0-47.03194.36.2
10987206.0-46.53154.05.9
11183200.0-46.43184.65.8
11351195.0-46.23205.15.7
11559189.0-46.03225.76.2
11702185.0-45.93236.15.7
11810182.0-45.83246.45.2
11996177.0-45.63257.05.7
12072175.0-45.53256.95.9
12187172.0-45.43246.86.2
12384167.0-45.23236.66.0
12883155.0-44.83216.16.9
12969153.0-44.73206.06.8
13102150.0-44.63196.06.7
13147149.0-44.53186.06.6
13329145.0-44.33176.06.9
13685137.5-44.03136.06.8
14062130.0-43.63106.06.7
14114129.0-43.63106.06.7
14326125.0-43.43116.27.4
14772117.0-42.93136.77.0
15037112.5-42.73156.97.3
15067112.0-42.73156.97.4
15127111.0-42.63157.07.3
15833100.0-41.93175.96.8
1636292.5-41.43205.06.5
1639992.0-41.43215.06.4
1654890.0-41.23264.96.9
1662489.0-41.23284.97.2
1687385.8-40.93364.97.4
1701784.0-40.83405.08.3
1726581.0-40.53394.79.9
1734980.0-40.53384.510.5
1761077.0-40.23364.212.2
1773575.6-40.13354.012.3
1826170.0-39.63504.013.1
1843068.3-39.43554.013.2
1876965.0-39.124.013.4
1915161.5-35.5104.013.7
1932460.0-33.8134.113.8
1956358.0-31.6164.314.0
1969956.9-30.3184.413.8
1994155.0-29.3214.613.5
2017953.2-28.3244.813.2
2035751.9-27.5265.013.4
2062550.0-28.4295.213.7
2122046.0-30.3345.914.4
2134545.2-30.7356.014.4
2137645.0-30.8356.014.4
2169843.0-31.9306.014.4
2205340.9-31.5256.014.4
2221040.0-31.3315.714.4
2266837.5-30.7505.014.3
2276337.0-30.6555.014.3
2305835.5-30.3565.014.3
2315935.0-30.1565.014.2
2368732.5-29.5575.013.2
2425930.0-28.8595.012.2
2470328.2-28.3605.011.4
2475428.0-28.2605.011.3
2485727.6-28.1605.011.2
2488327.5-28.1605.011.1
2528626.0-28.1525.010.6
2556725.0-28.0475.010.2
2565424.7-28.0455.010.1
2571224.5-28.0455.010.0
2586024.0-28.0465.110.1
2601223.5-28.0475.110.3
2648522.0-27.9505.29.5
2706320.3-27.9535.48.5
2717020.0-27.9535.58.4
2753919.0-27.8555.68.1
2792718.0-27.8575.77.8
2833817.0-27.7595.97.4
2864116.3-27.7606.07.2