Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1985-12-01 12:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.510962, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1985-12-01T12:00:00 * Date/Time End: 1985-12-01T12:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 31954 m
Event(s):
GF_8827 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1985-12-01T12:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 10599 m, total ozone 212.2 DU
Size:
534 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130967.00.0302.00.6
272950.0-1.6462.40.8
629908.0-5.7673.81.1
698900.0-6.5704.11.1
899877.0-8.8755.01.1
1140850.0-11.5934.21.1
1368825.0-14.11163.91.0
1601800.0-15.81384.31.0
2183740.0-20.21707.00.9
2593700.0-23.31897.91.0
2901671.0-25.62009.01.0
3253639.0-28.21908.01.0
3287636.0-28.51917.61.0
3458621.0-29.91965.71.0
3633606.0-26.32063.91.0
3705600.0-26.72133.21.0
4124566.0-29.23153.01.1
5001500.0-34.33227.41.1
5029498.0-34.53227.61.1
6533400.0-43.332415.20.9
7729334.0-50.332521.30.8
7906325.0-51.532522.20.7
8422300.0-55.232524.80.7
8927277.0-58.732527.40.7
9252263.0-60.532529.00.7
9566250.0-62.332528.60.7
9999233.0-64.732528.00.7
10211225.0-65.932425.90.7
10265223.0-66.232425.40.7
10599211.0-68.132322.21.7
10921200.0-67.832119.02.7
11262189.0-67.431815.83.7
11556180.0-67.131513.03.9
11726175.0-66.931412.44.0
12009167.0-66.631311.34.2
12660150.0-65.93089.03.9
12866145.0-65.63058.33.8
13189137.5-65.33017.23.8
13211137.0-65.33017.13.8
13256136.0-65.23007.03.8
13438132.0-65.02966.63.7
13770125.0-64.72885.93.8
14123118.0-64.32775.44.0
14415112.5-64.02665.13.7
14838105.0-63.52505.03.3
15138100.0-62.42455.03.0
1516999.5-62.32445.03.0
1558893.0-60.82375.13.7
1579390.0-60.02335.13.8
1633882.5-58.02255.44.2
1653380.0-57.32225.54.6
1720372.0-54.92136.05.8
1738370.0-54.22116.15.2
1786065.0-52.52066.66.0
1819861.7-51.32026.96.7
1838060.0-50.62017.16.7
1889055.5-48.71977.76.9
1895055.0-48.51967.87.0
1913253.5-47.91958.07.3
1951450.5-46.51948.08.0
1958050.0-46.21948.08.1
1971549.0-45.71938.08.4
2028545.0-43.71928.09.0
2075042.0-42.01908.09.6
2083141.5-41.71908.09.4
2108140.0-40.81857.99.1
2116739.5-40.41847.99.0
2152237.5-39.21777.98.9
2186035.7-37.91708.08.9
2199735.0-37.41698.78.8
2209634.5-37.11699.38.8
2219734.0-36.71689.88.8
2251132.5-34.916711.58.7
2307430.0-31.816514.58.5
2316929.6-31.216515.08.5
2343828.5-29.716214.38.4
2351328.2-29.316114.19.2
2356428.0-29.116014.09.7
2369327.5-28.715913.711.1
2390526.7-27.915613.38.7
2409626.0-27.215312.98.6
2437925.0-26.214912.48.5
2461524.2-25.314512.08.4
2467524.0-25.114612.38.4
2476723.7-24.814712.88.4
2495423.1-24.115013.78.7
2531022.0-23.715415.79.3
2554621.3-23.515617.09.7
2565021.0-23.415717.69.9
2600720.0-22.916019.69.9
2608119.8-22.816020.09.9
2638419.0-22.415120.19.9
2674118.1-21.914021.09.9
2678118.0-21.814020.69.9
2720317.0-21.313316.19.3
2751316.3-20.812513.08.8
2765116.0-20.712812.38.6
2774415.8-20.513011.98.5
2822814.8-19.914510.0
2864114.0-19.315111.2
2891213.5-18.915512.0
2919313.0-18.615014.4
2972912.1-17.814519.0
2979112.0-17.814218.2
3037511.1-17.010514.0
3044311.0-16.910613.1
3072110.6-16.51109.4
3116010.0-16.11354.0
319549.0-15.41487.3