Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1990-11-13 00:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.510893, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1990-11-13T00:00:00 * Date/Time End: 1990-11-13T00:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 28652 m
Event(s):
GF_9124 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1990-11-13T00:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 10816 m, total ozone 125.6 DU
Size:
525 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130974.0-6.71406.01.8
219963.0-6.41605.01.7
325950.0-6.01674.31.7
400941.0-5.71743.91.7
704905.0-7.22153.01.7
747900.0-7.42252.91.7
852888.0-8.02503.01.7
1190850.0-9.72252.61.6
1656800.0-12.01893.01.6
2017763.0-13.81723.91.6
2067758.0-14.11704.01.5
2373728.0-15.62155.01.5
2668700.0-17.12295.91.4
2689698.0-17.22306.01.4
3570620.0-21.62248.71.1
3630615.0-21.92238.91.1
3799601.0-23.12239.41.1
3811600.0-23.22239.51.1
5120500.0-32.921913.61.1
5334485.0-34.421814.31.1
6213427.0-40.921717.10.9
6654400.0-44.221618.50.9
6909385.0-46.121619.30.9
6996380.0-46.821619.60.9
8375307.0-58.121524.00.8
8520300.0-59.321623.90.8
9082274.0-63.921923.80.7
9172270.0-64.622023.70.7
9379261.0-66.122123.70.7
9639250.0-67.822323.70.7
10059233.0-70.622523.60.7
10188228.0-71.522623.60.9
10266225.0-71.522723.61.0
10562214.0-71.322823.71.4
10816205.0-72.523023.71.8
10961200.0-72.223123.82.0
11518182.0-70.823423.92.7
11650178.0-70.523524.02.8
11751175.0-70.323523.92.9
11994168.0-69.723623.73.0
12247161.0-70.323723.53.1
12667150.0-71.223823.22.9
13180137.5-72.424022.82.5
13420132.0-72.924022.72.4
13740125.0-72.524122.42.2
14361112.5-71.624322.01.8
14657107.0-71.224421.91.6
15058100.0-70.624621.61.3
1526996.5-70.324621.51.2
1546393.4-70.024721.41.4
1568490.0-69.724821.31.4
1588087.1-69.524921.21.4
1607584.3-69.224921.11.6
1624082.0-68.925021.01.7
1638880.0-68.725321.51.8
1698772.4-67.926223.82.1
1719070.0-67.226424.72.2
1725169.3-67.026525.02.3
1735668.1-66.726325.12.3
1763965.0-65.825825.62.5
1780063.3-65.225526.02.6
1812760.0-64.126023.72.8
1838857.5-63.326522.03.0
1839957.4-63.226522.13.0
1866255.0-62.426623.43.0
1903351.8-61.226725.23.0
1925350.0-60.426826.43.3
1941848.7-59.926927.23.6
1991345.0-58.227029.73.4
1996944.6-58.127030.03.4
2017143.2-57.427130.23.3
2020043.0-57.327130.23.3
2066040.0-54.827330.84.1
2100637.9-53.027531.24.7
2107537.5-52.627531.34.8
2152335.0-50.227731.85.1
2154234.9-50.127731.85.1
2181033.5-49.327832.25.3
2200932.5-48.827932.55.3
2238430.7-47.728033.05.5
2253730.0-47.327934.45.5
2299428.0-45.927538.85.6
2301827.9-45.927539.05.6
2348926.0-44.527335.55.8
2356725.7-44.327334.95.8
2364625.4-43.827234.45.8
2375325.0-43.127233.65.8
2402924.0-41.327031.65.9
2434922.9-39.226829.35.9
2462522.0-37.426727.35.8
2481621.4-36.126526.05.6
2491521.1-35.526726.25.6
2528720.0-36.327527.25.3
2564219.0-37.128228.65.1
2571518.8-37.328429.05.0
2601618.0-36.028930.64.8
2609417.8-35.629031.04.8
2633317.2-34.529131.74.6
2641517.0-34.229131.94.6
2684116.0-32.329333.14.8
2729715.0-31.629534.45.0
2778614.0-30.829635.94.7
2831313.0-30.029837.54.4
2836812.9-29.929837.64.4
2865212.4-26.929938.54.3