Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Ólafsson, Jón; Takahashi, Taro (2006): Hydrochemistry measured on water bottle samples at station B2/84_177 during the MRI-LDEO cooperative study. Marine Research Institute, Reykjavik / Iceland, PANGAEA, https://doi.org/10.1594/PANGAEA.400815

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Chipman, D W; Marra, John; Takahashi, Taro (1993): Primary production at 47°N and 20°W in the North Atlantic Ocean: a comparison between the 14C incubation method and the mixed layer budget. Deep Sea Research Part II: Topical Studies in Oceanography, 40(1-2), 151-169, https://doi.org/10.1016/0967-0645(93)90011-B
Grasshoff, Klaus (1970): A simultaneous multiple channel system for nutrient analysis in seawater with analog and digital data record. Technicon International Congress 1969, 11, 133-145
Murphy, Judith A; Riley, J P (1962): A modified single solution method for the determination of phosphate in natural waters. Analytica Chimica Acta, 27, 31-36, https://doi.org/10.1016/S0003-2670(00)88444-5
Takahashi, Taro; Ólafsson, Jón; Goddard, J G; Chipman, D W; Sutherland, Stewart C (1993): Seasonal variation of CO2 and nutrient salts over the high latitude oceans: A comparative study. Global Biogeochemical Cycles, 7(4), 843-878, https://doi.org/10.1029/93GB02263
Coverage:
Latitude: 68.000000 * Longitude: -18.833300
Date/Time Start: 1984-03-16T05:00:00 * Date/Time End: 1984-03-16T05:00:00
Minimum DEPTH, water: m * Maximum DEPTH, water: 990 m
Event(s):
B2/84_177 (46BS1984-2_177) * Latitude: 68.000000 * Longitude: -18.833300 * Date/Time: 1984-03-16T05:00:00 * Elevation: -1050.0 m * Location: North Atlantic * Campaign: B02/84 * Basis: Bjarni Saemundsson * Method/Device: CTD/Rosette (CTD-RO)
Comment:
For pCO2 measurements were about 0.5 liter of air equilibrated with sample. Sample volume 4. Nutrient samples are collected in 250 ml soft low density polyethylene acid washed bottles. They are kept refrigerated until analysis if it was not carried out soon after sampling. Otherwisee samples are stored at -20°C.
Size:
53 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth water [m]

Temp [°C]

Sal

Press [dbar]

Density [kg/m3]

O2 [µmol/l]

TCO2 [µmol/l]

pCO2water_SST_wet [µatm]
0-0.90034.6400.01027.858362.632183.2295.000
5-1.02034.6435.01027.865365.31
20-0.75034.69020.01027.892362.63
50-0.71034.70250.01027.900359.06
100-0.10034.813101.01027.961
1500.35034.857151.01027.971333.60
1980.72034.915199.01027.996322.44
2970.40034.901299.01028.004323.78
3960.32034.904399.01028.011321.10
594-0.08034.915598.01028.042320.20
990-0.620998.0