Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Whitmarsh, Robert B; Beslier, Marie-Odile; Wallace, Paul J; Shipboard Scientific Party (2005): X-ray fluorescence on samples of ODP Hole 173-1067A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.271463

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
ODP/TAMU (2005): JANUS Database. Ocean Drilling Program, Texas A&M University, College Station TX 77845-9547, USA; (data copied from Janus 2005-02 to 2005-06), http://www-odp.tamu.edu/database/
Whitmarsh, Robert B; Beslier, Marie-Odile; Wallace, Paul J; et al. (1998): Proceedings of the Ocean Drilling Program, 173 Initial Reports. Proceedings of the Ocean Drilling Program, Ocean Drilling Program, 173, online, https://doi.org/10.2973/odp.proc.ir.173.1998
Project(s):
Coverage:
Latitude: 40.682500 * Longitude: -11.595830
Date/Time Start: 1997-05-01T22:45:00 * Date/Time End: 1997-05-10T18:15:00
Minimum DEPTH, sediment/rock: 764.02 m * Maximum DEPTH, sediment/rock: 853.04 m
Event(s):
173-1067A * Latitude: 40.682500 * Longitude: -11.595830 * Date/Time Start: 1997-05-01T22:45:00 * Date/Time End: 1997-05-10T18:15:00 * Elevation: -5020.9 m * Penetration: 855.6 m * Recovery: 77.67 m * Location: South Atlantic Ocean * Campaign: Leg173 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 23 cores; 207.6 m cored; 648 m drilled; 37.4 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Depth, compositeDepth compmcdShipboard Scientific Party
Sample code/labelSample labelShipboard Scientific PartyDSDP/ODP/IODP sample designation
Sample commentSample commentShipboard Scientific PartyX-ray fluorescence (XRF)
Loss on ignitionLOI%Shipboard Scientific PartyX-ray fluorescence (XRF)Bead_loi
Silicon dioxideSiO2%Shipboard Scientific PartyX-ray fluorescence (XRF)
Titanium dioxideTiO2%Shipboard Scientific PartyX-ray fluorescence (XRF)
Aluminium oxideAl2O3%Shipboard Scientific PartyX-ray fluorescence (XRF)
Iron oxide, Fe2O3Fe2O3%Shipboard Scientific PartyX-ray fluorescence (XRF)
10 Manganese oxideMnO%Shipboard Scientific PartyX-ray fluorescence (XRF)
11 Magnesium oxideMgO%Shipboard Scientific PartyX-ray fluorescence (XRF)
12 Calcium oxideCaO%Shipboard Scientific PartyX-ray fluorescence (XRF)
13 Sodium oxideNa2O%Shipboard Scientific PartyX-ray fluorescence (XRF)
14 Potassium oxideK2O%Shipboard Scientific PartyX-ray fluorescence (XRF)
15 Phosphorus pentoxideP2O5%Shipboard Scientific PartyX-ray fluorescence (XRF)
16 NiobiumNbmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
17 ZirconiumZrmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
18 YttriumYmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
19 StrontiumSrmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
20 RubidiumRbmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
21 ZincZnmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
22 CopperCumg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
23 NickelNimg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
24 ChromiumCrmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
25 VanadiumVmg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
26 CeriumCemg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
27 BariumBamg/kgShipboard Scientific PartyX-ray fluorescence (XRF)
28 CommentCommentShipboard Scientific PartyX-ray fluorescence (XRF)
Size:
450 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Depth comp [mcd]

Sample label

Sample comment

LOI [%]

SiO2 [%]

TiO2 [%]

Al2O3 [%]

Fe2O3 [%]
10 
MnO [%]
11 
MgO [%]
12 
CaO [%]
13 
Na2O [%]
14 
K2O [%]
15 
P2O5 [%]
16 
Nb [mg/kg]
17 
Zr [mg/kg]
18 
Y [mg/kg]
19 
Sr [mg/kg]
20 
Rb [mg/kg]
21 
Zn [mg/kg]
22 
Cu [mg/kg]
23 
Ni [mg/kg]
24 
Cr [mg/kg]
25 
V [mg/kg]
26 
Ce [mg/kg]
27 
Ba [mg/kg]
28 
Comment
764.02764.02173-1067A-14R-1,22-26RUN M01; REP A2.9448.353.3715.0316.090.266.537.812.680.790.39101.3
764.02764.02173-1067A-14R-1,22-26RUN M01; REP B2.9448.533.3915.0416.130.276.507.822.750.770.40101.6
764.02764.02173-1067A-14R-1,22-26RUN T01; REP A1818844129141443458200427195
773.40773.40173-1067A-15R-1,0-4RUN M01; REP A0.5076.300.3411.332.140.021.130.755.810.210.0498.07
773.40773.40173-1067A-15R-1,0-4RUN M01; REP B0.5076.090.3411.352.050.011.150.745.820.200.0497.79
773.40773.40173-1067A-15R-1,0-4RUN T01; REP A9140231012125911223956116
784.18784.18173-1067A-16R-2,5-9RUN M01; REP A1.2852.302.1612.7413.290.196.069.462.591.090.29100.17
784.18784.18173-1067A-16R-2,5-9RUN M01; REP B1.2852.252.1812.7013.320.206.079.432.651.090.29100.18
784.18784.18173-1067A-16R-2,5-9RUN T01; REP A111413511821110175226740833122
802.81802.81173-1067A-18R-1,91-93RUN M04; REP A10.1347.311.7716.2011.750.355.1213.204.351.370.31101.72
802.81802.81173-1067A-18R-1,91-93RUN M04; REP B10.1347.221.7716.1211.750.365.0813.174.271.360.31101.41
802.81802.81173-1067A-18R-1,91-93RUN T02; REP A102073619413100524011526889163
814.07814.07173-1067A-19R-2,114-119RUN M03; REP A5.7051.921.8515.869.370.165.229.404.290.740.2299.03
814.07814.07173-1067A-19R-2,114-119RUN M03; REP B5.7052.011.8915.919.660.175.309.404.310.760.2299.62
814.07814.07173-1067A-19R-2,114-119RUN T02; REP A91372827598545783673974146
821.90821.90173-1067A-20R-1,80-83RUN M03; REP A1.4448.911.9914.3614.400.317.388.053.540.490.2199.74
821.90821.90173-1067A-20R-1,80-83RUN M03; REP B1.4448.932.0214.5014.450.327.498.063.470.480.30100
821.90821.90173-1067A-20R-1,80-83RUN T02; REP A7108371398125184803124072645
842.09842.09173-1067A-22R-2,43-47RUN M02; REP A1.1553.562.0014.0812.500.246.146.575.200.280.20100.77
842.09842.09173-1067A-22R-2,43-47RUN M02; REP B1.1553.642.0013.9012.420.256.046.505.030.270.20100.25
842.09842.09173-1067A-22R-2,43-47RUN T03; REP A712237169310926582404172913
852.30852.30173-1067A-23R-2,80-83RUN M05; REP A0.9649.902.3714.0114.030.277.048.513.840.360.32100.64
852.30852.30173-1067A-23R-2,80-83RUN M05; REP B0.9649.522.3713.9413.860.277.048.443.820.380.3299.95
852.30852.30173-1067A-23R-2,80-83RUN T03; REP A131964821621123996190371420
852.57852.57173-1067A-23R-2,107-111RUN M02; REP A1.0050.352.5513.1514.580.267.148.603.740.440.35101.16
852.57852.57173-1067A-23R-2,107-111RUN M02; REP B1.0050.252.5513.1514.590.257.118.593.930.450.36101.23
852.57852.57173-1067A-23R-2,107-111RUN T03; REP A121794715361183490224357340
853.04853.04173-1067A-23R-3,19-23RUN M03; REP A3.2441.883.1514.0720.630.3210.536.681.910.280.0799.53
853.04853.04173-1067A-23R-3,19-23RUN M03; REP B3.2441.773.1514.1320.650.3210.656.701.890.300.0799.62
853.04853.04173-1067A-23R-3,19-23RUN T03; REP A3042051784189126273458437120