Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Sandroni, Sonja; Anderson, Roger N; Honnorez, Jose J (2005): Minor-element chemical analyses of Hole 83-504B. PANGAEA, https://doi.org/10.1594/PANGAEA.263245

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
DSDP (1989): Data from the Deep Sea Drilling Project. Sediment, hard rock and reference files. National Geophysical Data Center, National Environmental Satellite, Data and Information Service, National Oceanic and Atmospheric Administration, U.S. Department of Commerce, 1, CD-ROM
Newmark, Robin L; Mottl, Michael J; Laverne, Christine; Kinoshita, Hajimu; Kempton, Pamela D; Emmermann, Rolf; Alt, Jeffrey C; Adamson, Andrew C; Anderson, Roger N; Honnorez, Jose J; Becker, K (1985): Initial Reports of the Deep Sea Drilling Project. Initial Reports of the Deep Sea Drilling Project, U.S. Government Printing Office, LXXXIII, 539 pp, https://doi.org/10.2973/dsdp.proc.83.1985
Project(s):
Coverage:
Latitude: 1.227200 * Longitude: -83.730200
Date/Time Start: 1981-11-22T00:00:00 * Date/Time End: 1982-01-02T00:00:00
Minimum DEPTH, sediment/rock: 844.18 m * Maximum DEPTH, sediment/rock: 1345.68 m
Event(s):
83-504B * Latitude: 1.227200 * Longitude: -83.730200 * Date/Time Start: 1981-11-22T00:00:00 * Date/Time End: 1982-01-02T00:00:00 * Elevation: -3460.0 m * Penetration: 1350 m * Recovery: 107.7 m * Campaign: Leg83 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: Leg 83 of DSDP was devoted entirely to coring and experiments in Hole 504B, the deepest borehole to date into the oceanic crust. Hole 504B now extends over a kilometer into basement, nearly twice as far as any other DSDP hole, and it is the only DSDP hole to have clearly penetrated into the intrusive sheeted dikes that underlie the extrusive pillow lavas of the upper oceanic crust. At Hole 504B, Leg 83 continued an ongoing DSDP effort that began during Legs 68, 69, and 70 in 1979, and also included part of Leg 92 in 1983. 71 cores; 514 m cored; 0 m drilled; 21 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Sample code/labelSample labelSandroni, SonjaDSDP/ODP/IODP sample designation
Sample IDSample IDSandroni, Sonja
AlterationAlterationSandroni, Sonja
Rock typeRockSandroni, Sonja
Lithology/composition/faciesLithologySandroni, SonjaVisual description
ScandiumScmg/kgSandroni, Sonja
VanadiumVmg/kgSandroni, Sonja
ChromiumCrmg/kgSandroni, Sonja
10 CobaltComg/kgSandroni, Sonja
11 NickelNimg/kgSandroni, Sonja
12 ZincZnmg/kgSandroni, Sonja
13 GalliumGamg/kgSandroni, Sonja
14 RubidiumRbmg/kgSandroni, Sonja
15 StrontiumSrmg/kgSandroni, Sonja
16 YttriumYmg/kgSandroni, Sonja
17 ZirconiumZrmg/kgSandroni, Sonja
18 NiobiumNbmg/kgSandroni, Sonja
19 LanthanumLamg/kgSandroni, Sonja
20 CeriumCemg/kgSandroni, Sonja
21 SamariumSmmg/kgSandroni, Sonja
22 EuropiumEumg/kgSandroni, Sonja
23 TerbiumTbmg/kgSandroni, Sonja
24 YtterbiumYbmg/kgSandroni, Sonja
25 LutetiumLumg/kgSandroni, Sonja
26 HafniumHfmg/kgSandroni, Sonja
27 TantalumTamg/kgSandroni, Sonja
28 Sample methodSample methodSandroni, Sonja
Size:
1215 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Sample label

Sample ID

Alteration

Rock

Lithology

Sc [mg/kg]

V [mg/kg]

Cr [mg/kg]
10 
Co [mg/kg]
11 
Ni [mg/kg]
12 
Zn [mg/kg]
13 
Ga [mg/kg]
14 
Rb [mg/kg]
15 
Sr [mg/kg]
16 
Y [mg/kg]
17 
Zr [mg/kg]
18 
Nb [mg/kg]
19 
La [mg/kg]
20 
Ce [mg/kg]
21 
Sm [mg/kg]
22 
Eu [mg/kg]
23 
Tb [mg/kg]
24 
Yb [mg/kg]
25 
Lu [mg/kg]
26 
Hf [mg/kg]
27 
Ta [mg/kg]
28 
Sample method
844.1883-504B-72-1,67-696Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT242.000398.00150.0076.0013.80.60065.0021.1044.000.80XF
853.7883-504B-73-1,126-1308Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT230.000437.00150.0068.0015.0<0.50061.0020.3042.000.60XF
853.7883-504B-73-1,126-1308Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT42.9058.301.0805.201.8700.7300.5502.1600.3401.3000.300NA
879.9683-504B-76-1,45-473Moderately alteredIgneousDOLERITIC APHYRIC BASALT227.000381.00166.0067.0014.80.50072.0022.2049.00<0.50XF
891.6283-504B-77-3,11-131AModerately alteredIgneousAPHYRIC BASALT311.000242.0092.0085.0015.50.60056.0026.4054.000.70XF
891.6283-504B-77-3,11-131AModerately alteredIgneousAPHYRIC BASALT48.1059.001.4905.402.4100.9500.7803.2000.5202.0000.400NA
920.1683-504B-81-1,64-687Moderately alteredIgneousOL-PLAG SP TO MOD PHYRIC BASALT283.000377.00116.00102.0015.2<0.50054.0023.1048.000.60XF
920.1683-504B-81-1,64-687Moderately alteredIgneousOL-PLAG SP TO MOD PHYRIC BASALT40.7052.501.2004.801.9201.0000.6702.4000.4201.4000.400NA
932.4083-504B-82-3,88-9210Moderately alteredIgneousOL-PLAG SP TO MOD PHYRIC BASALT264.000393.00138.0097.0015.4<0.50049.0022.3046.000.70XF
947.2883-504B-84-1,77-794BModerately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT275.000373.00121.0099.0014.8<0.50051.0022.7046.00<0.50XF
947.2883-504B-84-1,77-794BModerately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT41.7059.701.3005.101.9500.7800.5802.4000.4101.3000.400NA
957.6783-504B-85-2,66-687Moderately alteredIgneousOL-PLAG-CPX SP PHYRIC BASALT281.000351.00101.0092.0015.6<0.50062.0025.5056.000.70XF
967.7583-504B-87-1,73-776BModerately alteredIgneousOL-PLAG-CPX APHYRIC TO SP PHYRIC BASALT278.000205.0082.00108.0014.1<0.50059.0026.7054.000.80XF
977.6183-504B-88-1,109-1134EModerately alteredIgneousPLAG-CPX APHYRIC TO SP PHYRIC BASALT256.000330.00105.00104.0015.0<0.50075.0024.2068.003.80XF
977.6183-504B-88-1,109-1134EModerately alteredIgneousPLAG-CPX APHYRIC TO SP PHYRIC BASALT42.6049.203.2209.302.3800.8400.6902.6000.4202.0000.500NA
985.5383-504B-89-1,1-41Moderately alteredIgneousOL-PLAG APHYRIC TO MOD PHYRIC BASALT251.000427.00136.0097.0014.10.50069.0022.4055.000.50XF
994.6083-504B-90-1,8-122Moderately alteredIgneousOL-PLAG APHYRIC TO MOD PHYRIC BASALT305.000308.0095.0098.0014.5<0.50054.0025.5052.00<0.50XF
996.2483-504B-90-2,23-263Moderately alteredIgneousOL-PLAG APHYRIC TO MOD PHYRIC BASALT294.000352.0099.0098.0015.2<0.50055.0025.1054.000.50XF
997.0383-504B-90-2,101-10411Moderately alteredIgneousOL-PLAG APHYRIC TO MOD PHYRIC BASALT308.000204.0087.0087.0016.0<0.50047.0026.8052.000.70XF
999.5183-504B-90-4,49-536AModerately alteredIgneousPLAG APHYRIC TO SP PHYRIC BASALT250.000355.00102.0088.0014.60.60066.0022.6054.000.60XF
999.5183-504B-90-4,49-536AModerately alteredIgneousPLAG APHYRIC TO SP PHYRIC BASALT40.8050.001.6606.002.0601.0200.5502.1000.3701.9000.500NA
1004.8083-504B-91-1,127-13217Moderately alteredIgneousOL-PLAG-CPX SP PHYRIC BASALT262.000424.00132.00102.0014.80.50039.0020.4036.000.60XF
1004.8083-504B-91-1,127-13217Moderately alteredIgneousOL-PLAG-CPX SP PHYRIC BASALT40.9053.801.0303.901.6200.6700.5002.2300.3901.0000.200NA
1008.4183-504B-91-4,39-434Moderately alteredIgneousAPHYRIC BASALT257.000353.00108.00109.0014.5<0.50072.0022.8067.004.20XF
1022.5783-504B-93-1,106-10815AModerately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT270.000338.0097.0089.0015.0<0.50060.0023.2053.001.10XF
1024.8083-504B-93-3,27-323Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT236.000287.00134.0089.0016.4<0.50076.0033.00132.001.40XF
1024.8083-504B-93-3,27-323Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT38.5049.903.09012.303.6701.1900.9003.6000.5503.1000.500NA
1031.2083-504B-94-1,67-725Moderately alteredIgneousAPHYRIC BASALT269.000312.00117.0084.0015.9<0.50057.0023.9050.000.90XF
1034.9583-504B-94-3,143-14717Moderately alteredIgneousOL-CPX SP TO MOD PHYRIC BASALT303.000256.0091.00104.0015.40.50047.0026.7054.000.50XF
1040.8983-504B-95-1,137-14012Moderately alteredIgneousOL-PLAG SP PHYRIC BASALT280.000209.0089.0079.0015.0<0.50051.0025.2051.000.50XF
1072.6483-504B-99-1,112-11615Moderately alteredIgneousAPHYRIC BASALT292.000228.0092.0080.0014.90.50049.0024.1045.000.80XF
1082.2883-504B-10-2,26-314Moderately alteredIgneousOL-PLAG-CPX SP PHYRIC BASALT283.000490.00106.0077.0016.0<0.50048.0023.6043.000.80XF
1089.5383-504B-11-1,2-51Moderately alteredIgneousAPHYRIC BASALT302.000210.0087.0081.0015.0<0.50046.0023.7038.001.10XF
1091.1883-504B-11-2,16-202Moderately alteredIgneousOL-PLAG-CPX SP PHYRIC BASALT319.000168.0076.0084.0016.1<0.50052.0028.0056.00<0.50XF
1116.6783-504B-14-1,15-192Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT282.000228.0090.0079.0016.80.70054.0025.8051.000.60XF
1118.2683-504B-14-2,24-273Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT246.000363.00104.0070.0016.40.50061.0022.9049.000.90XF
1118.2683-504B-14-2,24-273Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT40.1050.601.3105.502.0900.9400.7002.9000.4401.7000.400NA
1145.7383-504B-17-2,71-757Moderately alteredIgneousAPHYRIC BASALT245.000333.00102.0067.0015.7<0.50058.0020.5043.000.50XF
1153.4683-504B-18-1,95-9711Moderately alteredIgneousAPHYRIC BASALT262.000314.0099.0075.0015.30.90059.0022.4046.000.50XF
1154.0183-504B-19-1,49-527Moderately alteredIgneousOL-PLAG-CPX APHYRIC TO SP PHYRIC BASALT272.000267.0090.0072.0015.9<0.50050.0023.3046.00<0.50XF
1154.0183-504B-19-1,49-527Moderately alteredIgneousOL-PLAG-CPX APHYRIC TO SP PHYRIC BASALT42.7051.501.3104.901.9700.7400.6402.7000.4201.300NA
1157.1883-504B-110-1,17-193Moderately alteredIgneousOL-PLAG-CPX APHYRIC TO SP PHYRIC BASALT256.000315.0099.0071.0015.2<0.50057.0022.5045.000.90XF
1166.3583-504B-112-1,34-365Moderately alteredIgneousOL-PLAG APHYRIC TO SP PHYRIC BASALT249.000427.00124.0084.0015.4<0.50051.0020.3038.000.70XF
1172.3183-504B-113-1,129-13314Moderately alteredIgneousOL-PLAG APHYRIC TO SP PHYRIC BASALT40.6058.301.2704.001.7300.6700.5602.3000.3901.1000.500NA
1172.3183-504B-113-1,129-13314Moderately alteredIgneousOL-PLAG APHYRIC TO SP PHYRIC BASALT254.000384.00116.0079.0015.0<0.50043.0020.1038.000.70XF
1185.4583-504B-116-1,43-467Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT286.000342.0099.0050.0015.9<0.50049.0024.8044.000.50XF
1185.4583-504B-116-1,43-467Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT46.1059.501.5905.402.3000.8800.7302.8000.4801.7000.300NA
1189.6183-504B-117-1,9-133Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT294.000292.0098.0079.0015.7<0.50049.0024.7047.000.70XF
1194.5183-504B-118-1,48-533Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT286.000297.00103.0073.0015.5<0.50051.0024.5047.001.10XF
1207.6783-504B-121-1,15-193Moderately alteredIgneousOL-PLAG APHYRIC TO SP PHYRIC BASALT320.000218.0090.0094.0016.0<0.50043.0026.9049.000.50XF
1223.1283-504B-123-1,60-636Moderately alteredIgneousOL-PLAG SP PHYRIC BASALT240.000178.00137.0075.0015.7<0.50060.0023.0043.001.00XF
1232.4983-504B-124-1,98-10011Moderately alteredIgneousOL-PLAG SP PHYRIC BASALT281.000339.0092.0066.0016.1<0.50045.0024.5043.000.70XF
1240.8483-504B-125-1,32-365Moderately alteredIgneousOL APHYRIC TO VERY SP PHYRIC BASALT296.000323.0092.0090.0015.2<0.50048.0025.9048.000.70XF
1249.9083-504B-126-1,38-415Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT220.000427.00150.0077.0014.7<0.50064.0018.7040.000.80XF
1253.9083-504B-127-1,38-425Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT219.000416.00164.0066.0015.0<0.50061.0018.8040.000.70XF
1262.1783-504B-128-1,115-11812Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT217.000447.00169.0066.0014.8<0.50060.0018.1037.000.80XF
1270.7883-504B-129-1,76-816AModerately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT204.000532.00246.0068.0013.1<0.50054.0017.2036.000.50XF
1270.7883-504B-129-1,76-816AModerately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT36.80116.801.0904.101.5700.7100.4901.9000.3100.9000.400NA
1272.8183-504B-129-2,130-13211Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT298.000219.0083.0073.0016.4<0.50058.0025.7056.000.60XF
1279.1783-504B-130-1,15-202Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT218.000456.00160.0063.0015.1<0.50062.0018.2039.000.50XF
1282.9783-504B-130-3,94-999BModerately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT196.000389.00211.0065.0014.4<0.50055.0018.2037.000.60XF
1287.5583-504B-131-1,3-71Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT167.000451.00157.0076.0013.9<0.50058.0018.1038.000.90XF
1296.4283-504B-132-1,141-14418Moderately alteredIgneousOL-PLAG-CPX SP PHYRIC BASALT261.000395.00127.0078.0014.8<0.50057.0022.5044.000.80XF
1304.1383-504B-133-1,10-152Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT256.000382.00122.0074.0015.4<0.50059.0022.3044.000.80XF
1305.0383-504B-133-1,101-10613Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT287.000317.0089.0076.0015.6<0.50045.0024.9045.000.70XF
1305.0383-504B-133-1,101-10613Moderately alteredIgneousOL-PLAG-CPX MOD PHYRIC BASALT34.9066.001.2504.302.1300.8000.7102.8000.4601.5000.500NA
1313.7383-504B-134-1,72-749Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT269.000286.00102.0076.0015.9<0.50058.0023.9049.000.90XF
1322.0683-504B-136-1,4-71Moderately alteredIgneousAPHYRIC BASALT307.000177.0084.00101.0015.60.60058.0026.6058.001.00XF
1327.1483-504B-137-1,11-162Moderately alteredIgneousOL-PLAG-CPX HI PHYRIC BASALT225.000424.00154.0073.0014.3<0.50061.0019.3042.000.90XF
1327.9583-504B-137-1,93-979Moderately alteredIgneousOL-PLAG-CPX HI PHYRIC BASALT222.000457.00143.0067.0014.7<0.50061.0019.4040.000.70XF
1332.6583-504B-138-1,62-678Moderately alteredIgneousOL-PLAG SP PHYRIC BASALT233.000417.00133.0072.0014.5<0.50059.0020.1041.000.60XF
1341.4183-504B-140-1,40-425Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT326.000267.0091.0071.0015.4<0.50051.0020.8059.001.00XF
1341.4183-504B-140-1,40-425Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT44.6074.101.7006.202.4701.1400.8003.1000.5101.6000.900NA
1345.6883-504B-141-1,16-203Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT239.000384.00120.0066.0015.8<0.50060.0020.6042.000.60XF
1345.6883-504B-141-1,16-203Moderately alteredIgneousOL-PLAG-CPX SP TO MOD PHYRIC BASALT40.6054.802.2206.101.8000.7900.5202.0000.3801.3000.600NA