Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Byerly, Gary R; Donelly, Thomas W; Francheteau, Jean; Flower, Martin F J (2005): Major-element chemical analyses of Hole 53-418A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.262111

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Donnelly, Thomas W; Francheteau, Jean; Bryan, Wilfred B; Robinson, P; Flower, M; Salisbury, Matthew H; et al. (1980): Initial Reports of the Deep Sea Drilling Project, 51/52/53. Initial Reports of the Deep Sea Drilling Project, U.S. Government Printing Office, 51/52/53, 718 pp + 1613 pp, https://doi.org/10.2973/dsdp.proc.515253.1980
DSDP (1989): Data from the Deep Sea Drilling Project. Sediment, hard rock and reference files. National Geophysical Data Center, National Environmental Satellite, Data and Information Service, National Oceanic and Atmospheric Administration, U.S. Department of Commerce, 1, CD-ROM
Project(s):
Coverage:
Latitude: 25.035000 * Longitude: -68.057300
Date/Time Start: 1977-03-15T00:00:00 * Date/Time End: 1977-03-15T00:00:00
Minimum DEPTH, sediment/rock: 570.60 m * Maximum DEPTH, sediment/rock: 865.79 m
Event(s):
53-418A * Latitude: 25.035000 * Longitude: -68.057300 * Date/Time: 1977-03-15T00:00:00 * Elevation: -5514.0 m * Penetration: 868 m * Recovery: 234 m * Campaign: Leg53 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 39 cores; 306.4 m cored; 0 m drilled; 76.4 % recovery
Parameter(s):
Size:
1019 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Sample label

Sample ID

Alteration

Rock

Lithology

SiO2 [%]

Al2O3 [%]

FeO [%]
10 
MgO [%]
11 
CaO [%]
12 
Na2O [%]
13 
K2O [%]
14 
TiO2 [%]
15 
P2O5 [%]
16 
Sample method
17 
Method comm
18 
Comment
570.6053-418A-49-1,10-02FreshIgneousGLASSY RIND50.2715.2710.297.9212.472.270.081.220.12PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
571.2753-418A-49-1,77-04FreshIgneousGLASSY RIND50.4915.1010.388.0112.452.210.081.200.13PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
575.2453-418A-50-2,24-01CFreshIgneousGLASSY RIND49.7715.2110.098.0612.332.260.111.200.10PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
575.7953-418A-50-2,79-05FreshIgneousGLASSY RIND50.3315.6310.428.0912.382.310.071.220.11PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
578.2753-418A-50-4,27-03FreshIgneousGLASSY RIND50.7315.2610.137.9312.302.210.091.230.10PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
580.0253-418A-50-5,52-03BFreshIgneousGLASSY RIND50.7015.1810.397.9912.362.210.081.220.10PRFTTTFTT FF1FFFPLAG-OL MOD PHYRIC BASALT
586.1353-418A-51-3,23-02CFreshIgneousGLASSY RIND51.0915.4510.588.1312.322.200.081.280.10PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
598.9553-418A-52-5,75-06FreshIgneousGLASSY RIND50.5514.9210.478.0212.202.310.101.230.10PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
602.8553-418A-53-1,125-010FreshIgneousGLASSY RIND50.5815.1910.697.7212.302.410.091.280.12PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
613.1853-418A-54-2,68-06FreshIgneousGLASSY RIND50.5814.2111.467.2111.702.310.111.570.12PRFTTTFTT FF1FFFPLAG-OL MOD PHYRIC BASALT
626.0253-418A-55-4,112-09FreshIgneousGLASSY RIND50.7014.6010.527.3812.382.330.111.370.13PRFTTTFTT FF1FFFOL-PLAG SPARSELY PHYRIC BASALT
627.5053-418A-55-5,110-07AFreshIgneousGLASSY RIND50.5414.4010.647.4912.222.260.111.390.14PRFTTTFTT FF1FFFOL-PLAG SPARSELY PHYRIC BASALT
628.0553-418A-55-6,15-01FreshIgneousGLASSY RIND51.2414.6510.617.6112.062.380.111.380.13PRFTTTFTT FF1FFFOL-PLAG SPARSELY PHYRIC BASALT
637.0953-418A-56-5,129-05FreshIgneousGLASSY RIND49.9914.1711.437.0511.662.380.141.540.12PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
641.6353-418A-57-2,113-04AFreshIgneousGLASSY RIND50.6614.2211.317.3211.682.370.141.570.12PRFTTTFTT FF1FFFPLAG-OL MOD PHYRIC BASALT
644.3053-418A-57-4,80-06AFreshIgneousGLASSY RIND50.9514.0611.707.1511.922.370.121.600.12PRFTTTFTT FF1FFFPLAG-OL MOD PHYRIC BASALT
648.7653-418A-58-1,56-05AFreshIgneousGLASSY RIND50.4514.4611.856.9511.562.410.111.640.16PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
649.9153-418A-58-2,21-01CFreshIgneousGLASSY RIND50.3614.6611.846.9211.502.470.121.670.15PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
649.9853-418A-58-2,28-02FreshIgneousGLASSY RIND50.6713.9911.766.8111.572.450.121.740.15PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
650.0253-418A-58-2,32-03AFreshIgneousGLASSY RIND51.2214.2812.087.0011.572.380.131.770.16PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
650.2053-418A-58-2,50-03BFreshIgneousGLASSY RIND50.9414.2211.726.8811.572.460.131.730.15PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
660.5153-418A-59-3,11-02FreshIgneousGLASSY RIND50.6414.2311.746.8411.582.410.131.750.14PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
661.9353-418A-59-4,3-01AFreshIgneousGLASSY RIND50.9314.3811.776.8811.832.510.141.720.14PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
665.0653-418A-59-6,16-01BFreshIgneousGLASSY RIND51.0414.1511.736.9911.462.420.111.710.13PRFTTTFTT FF1FFFPLAG-OL MOD PHYRIC BASALT
667.8453-418A-60-1,84-01GFreshIgneousGLASSY RIND50.4214.3711.457.0911.472.480.151.650.13PRFTTTFTT FF1FFFPLAG-OL-CPX PHYRIC BASALT
669.1653-418A-60-2,66-02FreshIgneousGLASSY RIND50.4714.2511.726.9611.602.390.131.680.15PRFTTTFTT FF1FFFPLAG-CPX MOD PHYRIC BASALT
670.3453-418A-60-3,34-02FreshIgneousGLASSY RIND50.2414.2211.576.8711.632.450.131.650.17PRFTTTFTT FF1FFFPLAG-CPX MOD PHYRIC BASALT
686.2753-418A-62-1,27-01CFreshIgneousGLASSY RIND50.8714.3111.747.0511.762.400.121.710.16PRFTTTFTT FF1FFFPLAG-CPX-OL MOD PHYRIC BASALT
688.2353-418A-62-2,73-04FreshIgneousGLASSY RIND50.7714.3711.476.9211.572.440.121.700.17PRFTTTFTT FF1FFFPLAG-CPX-OL MOD PHYRIC BASALT
690.3653-418A-63-1,36-02FreshIgneousGLASSY RIND50.2714.5211.496.8811.642.490.131.650.15PRFTTTFTT FF1FFFPLAG-OL-CPX MOD PHYRIC BASALT
691.1453-418A-62-4,64-04FreshIgneousGLASSY RIND49.9914.6611.607.0711.502.350.101.600.16PRFTTTFTT FF1FFFPLAG-CPX-OL MOD PHYRIC BASALT
691.5453-418A-62-4,104-05FreshIgneousGLASSY RIND50.4414.4011.466.9911.642.440.121.680.14PRFTTTFTT FF1FFFPLAG-CPX-OL MOD PHYRIC BASALT
697.1953-418A-64-2,19-01BFreshIgneousGLASSY RIND50.5514.8810.837.5012.232.390.081.400.12PRFTTTFTT FF1FFFPLAG MOD PHYRIC BASALT
699.0053-418A-64-3,50-01EFreshIgneousGLASSY RIND50.9314.7410.957.5412.392.340.101.380.13PRFTTTFTT FF1FFFPLAG-OL PHYRIC BASALT
700.8253-418A-64-4,82-02FFreshIgneousGLASSY RIND49.9915.0010.587.5811.902.390.101.340.13PRFTTTFTT FF1FFFPLAG MOD PHYRIC BASALT
703.4253-418A-64-6,42-02EFreshIgneousGLASSY RIND50.9114.7610.667.3912.332.330.091.360.14PRFTTTFTT FF1FFFPLAG MOD PHYRIC BASALT
705.5453-418A-65-1,44-02DFreshIgneousGLASSY RIND50.6914.5810.677.3812.142.300.091.320.14PRFTTTFTT FF1FFFPLAG-OL MOD PHYRIC BASALT
706.2153-418A-65-1,111-06BFreshIgneousGLASSY RIND51.9714.4310.887.5312.202.420.081.440.13PRFTTTFTT FF1FFFPLAG-OL MOD PHYRIC BASALT
717.3653-418A-66-2,126-06FreshIgneousGLASSY RIND51.0714.3311.277.0511.922.380.101.550.14PRFTTTFTT FF1FFFPLAG-CPX PHYRIC BASALT
719.7553-418A-66-4,65-03AFreshIgneousGLASSY RIND50.7014.2411.417.3511.712.310.121.530.14PRFTTTFTT FF1FFFPLAG-CPX PHYRIC BASALT
725.1553-418A-67-1,105-02EFreshIgneousGLASSY RIND51.1914.3911.487.1612.072.370.111.550.14PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
728.9553-418A-67-4,35-03FreshIgneousGLASSY RIND50.8314.4011.197.0111.932.370.101.530.14PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
731.9553-418A-68-2,135-03FreshIgneousGLASSY RIND51.4714.2611.387.1111.972.370.101.550.16PRFTTTFTT FF1FFFPLAG-CPX PHYRIC BASALT
735.2053-418A-69-2,10-01BFreshIgneousGLASSY RIND50.9314.3211.427.0611.982.390.111.540.14PRFTTTFTT FF1FFFPLAG-OL-CPX PHYRIC BASALT
737.2353-418A-69-3,63-02AFreshIgneousGLASSY RIND52.0213.9411.557.2311.812.420.111.590.14PRFTTTFTT FF1FFFPLAG-OL-CPX PHYRIC BASALT
745.4653-418A-70-2,86-02AFreshIgneousGLASSY RIND51.1114.0711.577.1611.942.340.101.590.16PRFTTTFTT FF1FFFPLAG-OL-CPX PHYRIC BASALT
755.8253-418A-71-3,12-02FreshIgneousGLASSY RIND50.8714.2011.697.1711.932.310.101.580.14PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
758.0253-418A-71-4,82-04FreshIgneousGLASSY RIND51.1514.3211.427.2011.912.350.101.560.14PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
763.3453-418A-72-4,4-01AFreshIgneousGLASSY RIND51.1714.0711.467.1611.892.280.111.500.14PRFTTTFTT FF1FFFPLAG-OL-CPX PHYRIC BASALT
766.0753-418A-73-1,127-03GFreshIgneousGLASSY RIND50.7714.1510.997.1511.622.350.121.480.11PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
767.1353-418A-73-2,83-03HFreshIgneousGLASSY RIND51.0414.2711.407.2011.852.280.091.540.16PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
769.6853-418A-73-4,38-01DFreshIgneousGLASSY RIND50.5814.2010.977.0711.882.340.101.530.14PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
779.2453-418A-74-4,44-02AFreshIgneousGLASSY RIND51.1814.1011.317.0011.802.370.111.550.16PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
780.3553-418A-74-5,5-01IgneousGLASSY RIND51.1014.0011.237.0111.842.300.121.550.14PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
787.1453-418A-76-1,4-02JFreshIgneousGLASSY RIND50.7314.3410.597.3711.722.390.111.440.12PRFTTTFTT FF1FFFPLAG-CPX MOD PHYRIC BASALT
787.6053-418A-75-4,140-07EFreshIgneousGLASSY RIND50.7414.2410.767.1211.782.360.121.480.15PRFTTTFTT FF1FFFPLAG-CPX-OL PHYRIC BASALT
788.3753-418A-75-5,67-04FreshIgneousPLAG-OL MOD PHYRIC BRECCIATED GLASS50.5513.9811.027.1711.742.320.121.500.14PRFTTTFTT FF1FFFGLASSY RIND ANALYSIS
817.3853-418A-79-4,88-02DFreshIgneousGLASSY RIND52.1413.9211.697.2111.842.420.081.550.15PRFTTTFTT FF1FFFPLAG-OL-CPX PHYRIC BASALT
821.5653-418A-80-1,6-01FreshIgneousGLASSY RIND49.7915.189.987.9212.302.250.081.210.12PRFTTTFTT FF1FFFPLAG MOD PHYRIC BASALT
865.7953-418A-86-5,29-02FreshIgneousGLASSY RIND50.7614.3110.617.4112.112.230.121.320.16PRFTTTFTT FF1FFFAPHYRIC BASALT