Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Bougault, Henri; Aumento, Fabrizio; Melson, William G (2005): Major-element chemical analyses of Hole 37-332A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.262057

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
DSDP (1989): Data from the Deep Sea Drilling Project. Sediment, hard rock and reference files. National Geophysical Data Center, National Environmental Satellite, Data and Information Service, National Oceanic and Atmospheric Administration, U.S. Department of Commerce, 1, CD-ROM
Wright, T; Robinson, Paul T; Miles, G A; Hyndman, Roy D; Howe, Robert C; Flower, M; Fischer, Joseph F; Dmitriev, Leonid V; Bougault, Henri; Hall, James M; Aumento, Fabrizio; Melson, William G (1977): Initial Reports of the Deep Sea Drilling Project. Initial Reports of the Deep Sea Drilling Project, U.S. Government Printing Office, XXXVII, 1008 pp, https://doi.org/10.2973/dsdp.proc.37.1977
Project(s):
Coverage:
Latitude: 36.878700 * Longitude: -33.641000
Date/Time Start: 1974-06-17T00:00:00 * Date/Time End: 1974-06-17T00:00:00
Minimum DEPTH, sediment/rock: 104.43 m * Maximum DEPTH, sediment/rock: 428.93 m
Event(s):
37-332A * Latitude: 36.878700 * Longitude: -33.641000 * Date/Time: 1974-06-17T00:00:00 * Elevation: -1818.0 m * Penetration: 434.5 m * Recovery: 66.2 m * Location: North Atlantic/VALLEY * Campaign: Leg37 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 39 cores; 370.5 m cored; 0 m drilled; 17.9 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Sample code/labelSample labelBougault, HenriDSDP/ODP/IODP sample designation
Sample IDSample IDBougault, Henri
Rock typeRockBougault, Henri
Lithology/composition/faciesLithologyBougault, Henri
Silicon dioxideSiO2%Bougault, Henri
Aluminium oxideAl2O3%Bougault, Henri
Iron oxide, FeOFeO%Bougault, Henrigiven as FeO, total [%]
Magnesium oxideMgO%Bougault, Henri
10 Calcium oxideCaO%Bougault, Henri
11 Sodium oxideNa2O%Bougault, Henri
12 Potassium oxideK2O%Bougault, Henri
13 Titanium dioxideTiO2%Bougault, Henri
14 Manganese oxideMnO%Bougault, Henri
15 Phosphorus pentoxideP2O5%Bougault, Henri
16 Loss on ignitionLOI%Bougault, Henri
17 Water content, dry massWater dm%Bougault, Henriheated at 1050 °C
18 Water content, dry massWater dm%Bougault, Henriheated overnight at 110 °C
19 Carbon dioxideCO2%Bougault, Henri
20 Sample methodSample methodBougault, Henri
21 Method commentMethod commBougault, Henri
Size:
1024 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Sample label

Sample ID

Rock

Lithology

SiO2 [%]

Al2O3 [%]

FeO [%]
(given as FeO, total [%])

MgO [%]
10 
CaO [%]
11 
Na2O [%]
12 
K2O [%]
13 
TiO2 [%]
14 
MnO [%]
15 
P2O5 [%]
16 
LOI [%]
17 
Water dm [%]
(heated at 1050 °C)
18 
Water dm [%]
(heated overnight at 110 °C)
19 
CO2 [%]
20 
Sample method
21 
Method comm
104.4337-332A-6-2,92-94IgneousPLAG PHYRIC BASALT47.3422.834.485.6315.841.530.090.370.080.052.000.450.600.12XFFTFFFTT FT1FTF
111.6037-332A-7-1,8-11IgneousPLAG SPARSELY PHYRIC BASALT47.7314.268.457.0612.462.120.281.070.130.131.900.511.200.27XFFTFFFTT FT1FTF
111.9237-332A-7-1,41-435IgneousPLAG PHYRIC BASALT45.7720.775.035.6015.451.530.140.400.100.061.900.301.100.12XFFTFFFTT FT1FTF
112.4937-332A-7-1,98-100IgneousPLAG PHYRIC BASALT47.2821.245.305.9815.501.520.110.390.090.060.761.14XFFTFFFTT FT1FFF
113.0937-332A-7-2,7-10IgneousPLAG SPARSELY PHYRIC BASALT49.5913.509.566.5811.592.270.371.170.160.152.200.591.100.12XFFTFFFTT FT1FTF
121.3137-332A-8-1,30-314IgneousPLAG MOD PHYRIC BASALT48.7713.9910.436.7011.822.220.461.170.170.141.500.590.800.28XFFTFFFTT FT1FFF
121.9737-332A-8-1,95-9811IgneousAPHYRIC BASALT50.4614.029.916.9112.212.200.351.110.170.131.200.480.500.27XFFTFFFTT FT1FTF
123.6137-332A-8-2,109-11227IgneousAPHYRIC BASALT48.4413.739.426.7911.872.250.321.060.160.131.300.390.800.26XFFTFFFTT FT1FTF
131.1837-332A-9-1,67-687IgneousPLAG SPARSELY PHYRIC BASALT51.1814.499.766.9012.092.250.311.130.170.121.900.520.700.17XFFTFFFTT FT1FTF
145.1137-332A-10-CC,60-61IgneousPLAG-CPX MOD PHYRIC BASALT49.6914.5710.247.0911.672.220.471.180.170.141.700.780.700.12XFFTFFFTT FT1FFF
145.3137-332A-10-CC,80-815IgneousPLAG SPARSELY PHYRIC BASALT49.5514.299.966.5311.800.271.180.170.142.450.571.700.19XFFTFFFTT FT1FFF
150.3837-332A-11-1,87-884IgneousPLAG SPARSELY PHYRIC BASALT49.4214.658.707.8513.032.150.200.970.160.111.800.480.800.36XFFTFFFTT FT1FFF
160.0937-332A-12-1,107-110IgneousAPHYRIC BASALT49.5914.598.698.2012.792.080.100.910.130.112.300.521.800.06XFFTFFFTT FT1FTF
160.5737-332A-12-2,6-8IgneousAPHYRIC BASALT48.8114.478.518.2812.762.050.180.890.140.402.17XFFTFFFTT FT1FFF
160.7137-332A-12-2,20-21IgneousAPHYRIC BASALT49.0514.488.318.1912.872.240.140.920.160.112.300.541.800.14XFFTFFFTT FT1FTF
160.7137-332A-12-2,20-21IgneousAPHYRIC BASALT49.2214.688.398.2213.102.200.230.900.160.112.800.571.500.08XFFTFFFTT FT1FTF
161.1337-332A-12-2,61-64IgneousAPHYRIC BASALT49.2414.578.678.0413.312.280.170.900.150.102.000.611.200.10XFFTFFFTT FT1FFF
169.6437-332A-13-1,114-1151IgneousAPHYRIC BASALT49.4714.569.157.3012.402.230.281.050.150.141.600.580.900.09XFFTFFFTT FT1FTF
179.2537-332A-14-1,123-12612IgneousPLAG-CPX SPARSELY PHYRIC BASALT49.5013.879.207.0912.042.220.441.040.160.122.600.560.900.13XFFTFFFTT FT1FTF
189.1037-332A-15-CC,0-0IgneousPLAG-CPX-OL MOD PHYRIC BASALT49.1914.809.017.5912.762.030.311.040.160.110.900.480.400.09XFFTFFFTT FT1FFF
198.2537-332A-16-1,124-125IgneousAPHYRIC BASALT50.7114.539.007.2512.242.370.251.160.180.131.000.540.500.10XFFTFFFTT FT1FTF
207.2237-332A-17-1,72-739IgneousAPHYRIC BASALT48.7014.849.398.0912.272.150.151.230.170.121.100.500.700.09XFFTFFFTT FT1FFF
219.1037-332A-18-CC,0-0IgneousAPHYRIC BASALT50.4714.639.657.9612.182.110.161.030.150.12-0.400.370.09XFFTFFFTT FT1FTF
225.8637-332A-19-1,35-361IgneousAPHYRIC BASALT49.5414.019.437.1012.512.250.341.030.160.111.300.710.400.20XFFTFFFTT FT1FFF
237.6337-332A-20-2,112-1137IgneousAPHYRIC BASALT49.4814.518.997.8612.402.220.181.030.150.122.300.651.300.06XFFTFFFTT FT1FFF
245.0937-332A-21-1,57-604IgneousAPHYRIC BASALT49.6114.608.227.8912.692.190.200.990.140.121.600.430.700.24XFFTFFFTT FT1FFF
255.3737-332A-22-1,136-13716IgneousAPHYRIC BASALT49.3714.5110.117.2912.082.200.381.220.170.141.900.661.000.12XFFTFFFTT FT1FFF
264.5337-332A-23-1,100-105IgneousAPHYRIC BASALT50.1714.3810.036.5811.492.170.391.230.160.122.070.580.800.34XFFTFFFTT FT1FFF
274.2237-332A-24-1,120-125IgneousAPHYRIC BASALT50.4014.559.407.6912.382.070.241.080.150.131.600.470.700.20XFFTFFFTT FT1FFF
282.8737-332A-25-1,36-372IgneousPLAG-OL-CPX MOD PHYRIC BASALT49.0513.9110.127.2211.852.360.341.190.160.121.400.581.000.12XFFTFFFTT FT1FFF
292.4137-332A-26-1,39-42IgneousPLAG MOD PHYRIC BASALT49.0214.539.317.2412.192.260.311.230.160.152.600.521.300.34XFFTFFFTT FT1FTF
301.8637-332A-27-1,35-366IgneousPLAG MOD PHYRIC BASALT49.0314.6510.107.6412.142.210.331.250.170.161.200.470.700.17XFFTFFFTT FT1FTF
311.2837-332A-28-1,26-29IgneousPLAG-OL SPARSELY PHYRIC BASALT48.5616.448.417.3912.662.190.271.040.150.162.700.611.500.19XFFTFFFTT FT1FTF
311.9337-332A-28-1,91-9611IgneousPLAG-OL MOD PHYRIC BASALT48.2514.4910.057.6012.252.250.201.200.170.171.100.450.600.20XFFTFFFTT FT1FTF
313.1137-332A-28-2,59-621IgneousPLAG-CPX MOD PHYRIC BASALT48.7313.8210.057.1811.782.220.301.180.170.152.800.691.600.06XFFTFFFTT FT1FTF
314.3037-332A-28-3,28-31IgneousPLAG-OL SPARSELY PHYRIC BASALT49.0913.9210.127.2312.122.220.371.220.170.152.800.691.600.06XFFTFFFTT FT1FTF
320.6437-332A-29-1,13-142IgneousAPHYRIC BASALT47.1215.0610.076.9913.272.350.261.270.160.171.200.480.300.71XFFTFFFTT FT1FTF
320.7837-332A-29-1,26-29IgneousPLAG-OL PHYRIC BASALT49.9416.028.156.6312.802.090.361.030.150.121.180.460.500.14XFFTFFFTT FT1FFF
332.1337-332A-30-2,61-6528AIgneousPLAG PHYRIC BASALT47.7216.588.897.4012.891.840.301.030.150.141.100.420.700.09XFFTFFFTT FT1FTF
339.7437-332A-31-1,23-243IgneousPLAG PHYRIC BASALT49.2216.358.816.4612.662.290.361.030.150.131.200.590.500.07XFFTFFFTT FT1FFF
350.1037-332A-32-1,108-11114IgneousPLAG-OL PHYRIC BASALT49.4815.189.587.6512.182.070.291.220.160.131.500.570.800.05XFFTFFFTT FT1FTF
359.6637-332A-33-1,115-116IgneousPLAG PHYRIC BASALT48.3316.968.347.2413.092.130.171.020.150.131.200.490.700.08XFFTFFFTT FT1FFF
360.6337-332A-33-2,61-64IgneousPLAG MOD PHYRIC BASALT49.6114.538.107.0212.342.140.121.020.140.131.600.680.300.15XFFTFFFTT FT1FFF
360.9837-332A-33-2,95-1004IgneousAPHYRIC BASALT48.9114.2010.067.0011.962.180.191.070.170.140.552.21XFFTFFFTT FT1FFF
361.0137-332A-33-2,99-103IgneousAPHYRIC BASALT49.4016.208.477.2613.002.070.251.000.150.130.490.72XFFTFFFTT FT1FFF
370.8837-332A-34-2,136-13917IgneousPLAG MOD PHYRIC BASALT48.4914.709.137.4613.702.110.231.080.170.142.000.330.201.27XFFTFFFTT FT1FFF
387.6837-332A-36-1,66-699IgneousPLAG PHYRIC BASALT48.3116.758.487.0313.182.060.251.060.150.131.300.651.300.09XFFTFFFTT FT1FTF
397.9337-332A-37-1,141-1448IgneousPLAG-CPX-OL PHYRIIC BASALT49.7314.379.877.6211.972.170.161.120.170.152.300.470.400.28XFFTFFFTT FT1FTF
415.9037-332A-39-1,38-416IgneousPLAG-CPX PHYRIC BASALT50.0016.018.806.9212.732.190.201.020.150.121.740.560.500.11XFFTFFFTT FT1FFF
425.3137-332A-40-1,30-313IgneousPLAG-CPX SPARSELY PHYRIC BASALT47.7714.5710.107.3112.432.110.131.080.170.133.800.812.000.47XFFTFFFTT FT1FFF
426.2337-332A-40-1,121-124IgneousPLAG-AUGITE-OL PHYRIC BASALT48.1816.906.538.8315.261.480.230.560.110.082.300.560.500.81XFFTFFFTT FT1FTF
427.8337-332A-40-2,132-134IgneousAPHYRIC BASALT49.5514.3210.467.2811.572.180.271.180.180.141.900.721.400.33XFFTFFFTT FT1FFF
428.9337-332A-40-3,90-95IgneousPLAG-AUGITE-OL PHYRIC BASALT47.0514.576.0611.1213.731.400.080.520.110.072.020.390.600.58XFFTFFFTT FT1FFF