Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Furuta, Toshio; Cann, Joe R; White, S M; Langseth, Marcus G (2005): Paleomagnetic and rock magnetic measurements of igneous and metamorphic rocks of Hole 69-504B [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.261472

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
DSDP (1989): Data from the Deep Sea Drilling Project. Sediment, hard rock and reference files. National Geophysical Data Center, National Environmental Satellite, Data and Information Service, National Oceanic and Atmospheric Administration, U.S. Department of Commerce, 1, CD-ROM
Wilkens, Roy H; Schrader, Ed L; Sancetta, Constance A; Noack, Y; Mottl, Michael J; Moorby, S A; Migdisov, Areg A; Levi, Shaul; Laverne, Christine; Karato, Shun-ichiro; Jones, S C; Hubberten, Hans-Wolfgang; Furuta, Toshio; Borella, Peter E; Bender, Michael L; Beiersdorf, Helmut; Becker, Keir; Barrett, T J; Adamson, Andrew C; von Herzen, Richard P; Honnorez, Jose J; Zoback, Mark D; Ponomarev, Vladmir N; Pertsev, Nikolay N; Nekhoroshkov, Vladislav L; Natland, James H; Lawrence, James R; Anderson, Roger N; Cann, Joe R; White, S M; Langseth, Marcus G (1983): Initial Reports of the Deep Sea Drilling Project. U. S. Government Printing Office, Washington, LXIX, 864 pp, https://doi.org/10.2973/dsdp.proc.69.1983
Project(s):
Coverage:
Latitude: 1.227200 * Longitude: -83.730200
Date/Time Start: 1979-10-07T00:00:00 * Date/Time End: 1979-10-07T00:00:00
Minimum DEPTH, sediment/rock: 271.03 m * Maximum DEPTH, sediment/rock: 484.27 m
Event(s):
69-504B * Latitude: 1.227200 * Longitude: -83.730200 * Date/Time: 1979-10-07T00:00:00 * Elevation: -3460.0 m * Penetration: 489 m * Recovery: 262 m * Campaign: Leg69 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Sample code/labelSample labelFuruta, ToshioDSDP/ODP/IODP sample designation
Sample IDSample IDFuruta, Toshio
Lithology/composition/faciesLithologyFuruta, Toshio
NRM, IntensityInten (NRM)mA/mFuruta, Toshioreviewed and corrected (x 1000) by PANGAEA
NRM, InclinationIncl (NRM)degFuruta, Toshio
ChRM, InclinationIncl (ChRM)degFuruta, Toshio
NRM, median destructive field of natural remanent magnetization, alternating fieldMDF (NRM)mTFuruta, Toshio
Magnetic susceptibility, volumekappa10-6 SIFuruta, ToshioInitial susceptibility [gauss/oersteds] transformed to 10**-6 SI
10 Koenigsberger ratioQ-ratioA/mFuruta, Toshio
11 Sample methodSample methodFuruta, ToshioThermomagnetic curve
12 Curie temperatureCurie temp°CFuruta, Toshio
13 Hysteresis, saturation magnetization, per unit volumeMsmA/mFuruta, Toshio
14 Hysteresis, saturation remanence, per unit volumeMsrmA/mFuruta, Toshio
15 Coercive forceBcmTFuruta, Toshio
16 Coercivity of remanenceBcrmTFuruta, ToshioRemanent coercive force
17 Grain size descriptionGrain size descrFuruta, ToshioGrain size given in µm
18 CommentCommentFuruta, Toshio
Size:
2377 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Sample label

Sample ID

Lithology

Inten (NRM) [mA/m]

Incl (NRM) [deg]

Incl (ChRM) [deg]

MDF (NRM) [mT]

kappa [10-6 SI]
10 
Q-ratio [A/m]
11 
Sample method
12 
Curie temp [°C]
13 
Ms [mA/m]
14 
Msr [mA/m]
15 
Bc [mT]
16 
Bcr [mT]
17 
Grain size descr
18 
Comment
271.0369-504B-2-1,103-0233Igneous1.25013.56.225.1003900.530012.8PLAG-OL SPARSELY PHYRIC BASALT,ALT MOD
278.8869-504B-3-1,87-89250Igneous4.200-11.012.022.628.000Curie temperature is from the cooling curve185APHYRIC BASALT,ALT SLIGHT
278.8869-504B-3-1,87-89250IgneousCurie temperature is from the heating curve470
278.8869-504B-3-1,87-89250IgneousCurie temperature is from the heating curve3050.59800.154006.5210.517
279.0369-504B-3-1,103-0253Igneous3.75010.868.7003800.774012.0APHYRIC BASALT,ALT FRESH
279.0969-504B-3-1,108-110253Igneous7.1003.011.018.8514.000Curie temperature is from the heating curve3000.58600.135006.4615.414APHYRIC BASALT,ALT SLIGHT
279.0969-504B-3-1,108-110253IgneousCurie temperature is from the cooling curve485
279.0969-504B-3-1,108-110253IgneousCurie temperature is from the heating curve545
280.4469-504B-4-1,44-0271Igneous10.70017.54.3062.5003700.560022.2PLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT FRESH
281.0969-504B-4-1,108-110281Igneous9.500-18.026.07.5447.000Curie temperature is from the cooling curve340PLAG-OL MOD PHYRIC BASALT PILLOWS,ALT SLIGHT
281.0969-504B-4-1,108-110281IgneousCurie temperature is from the heating curve3100.23600.1080019.0027.55
281.0969-504B-4-1,108-110281IgneousCurie temperature is from the heating curve470BEARING,BASALT PILLOWS,ALT SLIGHT
281.7369-504B-4-2,23-0292Igneous4.4501.6368.5003800.200068.8PLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD
282.5269-504B-4-2,101-103304Igneous21.100-17.024.010.0577.000Curie temperature is from the heating curve2550.49600.1980015.8021.515PLAG-OL MOD PHYRIC BASALT PILLOWS,ALT MOD
282.5269-504B-4-2,101-103304IgneousCurie temperature is from the cooling curve200
283.9169-504B-4-3,91-0320Igneous6.70016.03.7744.7003700.567018.5PLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD
284.2369-504B-4-3,122-124323Igneous15.100-15.040.07.5476.000Curie temperature is from the heating curve480PLAG-OL MOD PHYRIC BASALT PILLOWS,ALT MOD
284.2369-504B-4-3,122-124323IgneousCurie temperature is from the heating curve3100.40200.1730045.0039.512
284.2369-504B-4-3,122-124323IgneousCurie temperature is from the cooling curve275
284.9269-504B-4-4,41-43330Igneous7.400-3.021.015.0817.000PLAG-OL MOD PHYRIC BASALT PILLOWS,ALT MOD
285.3069-504B-4-4,80-0336Igneous5.7005.7824.8003600.612015.8PLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD
286.7669-504B-4-5,76-0352Igneous3.00030.01.6047.2004000.173043.0PLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD
287.0669-504B-4-5,105-107355Igneous16.600-0.200.717.08.9260.0004201.470019.00PLAG-OL SPARSELY TO MODERATELY PHYRIC BASALT,
287.0669-504B-4-5,105-107355IgneousWITH ESSENTIAL CHROMITE,ALT MOD
287.2569-504B-4-5,124-126356Igneous10.700-16.023.012.5732.000Curie temperature is from the cooling curve490PLAG-OL MOD PHYRIC BASALT PILLOWS,ALT MOD
287.2569-504B-4-5,124-126356IgneousCurie temperature is from the heating curve520
287.2569-504B-4-5,124-126356IgneousCurie temperature is from the heating curve3000.46400.1780013.1021.0
289.9969-504B-5-1,47-50361Igneous19.500-71.20-70.914.58.5574.0003951.410017.70PLAG-OL PHYRIC BASALT,WITH ESSENTIAL CHROMITE,
289.9969-504B-5-1,47-50361IgneousALT MOD
290.0869-504B-5-1,57-59361Igneous12.800-9.017.012.5738.000Curie temperature is from the heating curve520PLAG-OL MOD PHYRIC PILLOW BASALT,ALT MOD
290.0869-504B-5-1,57-59361IgneousCurie temperature is from the heating curve2950.46600.1780010.0017.117
290.0869-504B-5-1,57-59361IgneousCurie temperature is from the cooling curve500
290.5969-504B-5-1,109-0369Igneous0.115064.7PLAG-OL MOD PHYRIC PILLOW BASALT,ALT MOD
291.1269-504B-5-2,10-13373Igneous2.070-32.40-28.89.014.455.0003502.640014.10PLAG-OL PHYRIC BASALT,WITH ESSENTIAL CHROMITE,
291.1269-504B-5-2,10-13373IgneousALT FRESH
291.4269-504B-5-2,41-43377Igneous17.600-15.018.010.0566.000Curie temperature is from the cooling curve270PLAG-OL MOD PHYRIC PILLOW BASALT,ALT MOD
291.4269-504B-5-2,41-43377IgneousCurie temperature is from the heating curve465
291.4269-504B-5-2,41-43377IgneousCurie temperature is from the heating curve3000.51800.2080012.2018.7
292.0869-504B-5-2,108-0383Igneous3500.774012.4PLAG-OL MOD PHYRIC PILLOW BASALT,ALT FRESH
293.1969-504B-5-3,69-0392Igneous3800.530026.7PLAG-OL MOD PHYRIC PILLOW BASALT,ALT FRESH
299.0669-504B-6-1,55-57403Igneous9.200-12.043.05.0366.000Curie temperature is from the heating curve2300.34800.1630015.5028.730PLAG-OL MOD PHYRIC PILLOW BASALT,ALT MOD
299.0669-504B-6-1,55-57403IgneousCurie temperature is from the cooling curve235
299.0669-504B-6-1,55-57403IgneousCurie temperature is from the heating curve495
299.5969-504B-6-1,109-0369Igneous1.9001.6529.000PLAG-OL MOD PHYRIC BASALT,ALT MOD
299.6969-504B-6-1,119-0410Igneous8.50040.01.46147.0003700.276049.3PLAG-OL MOD PHYRIC BASALT,ALT MOD
300.3769-504B-6-2,35-38416Igneous5.10014.518.85Curie temperature is from the heating curve2950.61400.241008.6013.828PLAG-OL PHYRIC BASALT,ALT MOD
300.3769-504B-6-2,36-38416Igneous5.000-12.014.518.8510.000PLAG-OL MOD PHYRIC PILLOW BASALT,ALT MOD
300.3769-504B-6-2,35-38416IgneousCurie temperature is from the cooling curve525
300.3769-504B-6-2,35-38416IgneousCurie temperature is from the heating curve555
300.9969-504B-6-2,99-0422Igneous4.2006.0317.5003600.87709.3PLAG-OL MOD PHYRIC BASALT,ALT MOD
301.0869-504B-6-2,108-0384Igneous14.60010.23.22114.000PLAG-OL MOD PHYRIC BASALT,ALT FRESH
301.2269-504B-6-2,122-0424Igneous5.00013.02.0461.7003800.545025.0PLAG-OL MOD PHYRIC BASALT,ALT MOD
307.8469-504B-7-1,33-35436Igneous11.700-6.055.03.77108.000Curie temperature is from the heating curve460PLAG-OL PHYRIC BASALT,ALT MOD
307.8469-504B-7-1,33-35436IgneousCurie temperature is from the heating curve3100.58000.1560035.0055.03
307.8469-504B-7-1,33-35436IgneousCurie temperature is from the cooling curve430
307.9569-504B-7-1,45-0437Igneous3.0004.1518.2000.164054.0PLAG-OL PHYRIC BASALT,ALT EXT
309.9969-504B-7-2,98-100464Igneous14.700-9.07.5470.000Curie temperature is from the cooling curve230PLAG-OL PHYRIC BASALT,ALT MOD
309.9969-504B-7-2,98-100464IgneousCurie temperature is from the heating curve465
309.9969-504B-7-2,98-100464IgneousCurie temperature is from the heating curve310
310.0069-504B-7-2,100-0464Igneous8.60025.05.4040.0003700.577024.2PLAG-OL PHYRIC BASALT,ALT MOD
310.9569-504B-7-3,45-0479Igneous3.6301.9945.9004200.207055.0PLAG-OL PHYRIC BASALT,ALT MOD
311.7869-504B-7-3,127-129489Igneous12.000-5.012.013.8230.000Curie temperature is from the heating curve2850.65800.206007.7012.0PLAG-OL PHYRIC BASALT,ALT MOD
311.7869-504B-7-3,127-129489IgneousCurie temperature is from the cooling curve215
311.7869-504B-7-3,127-129489IgneousCurie temperature is from the heating curve500
312.3669-504B-7-4,35-37495Igneous8.900-5.013.016.3419.000Curie temperature is from the cooling curve500PLAG-OL PHYRIC BASALT,ALT MOD
312.3669-504B-7-4,35-37495IgneousCurie temperature is from the heating curve530
312.3669-504B-7-4,35-37495IgneousCurie temperature is from the heating curve3000.64800.179007.7014.017
313.5469-504B-7-5,3-5509Igneous8.600-6.010.020.1116.000Curie temperature is from the heating curve495PLAG-OL PHYRIC BASALT,ALT FRESH
313.5469-504B-7-5,3-5509IgneousCurie temperature is from the heating curve3000.76200.142007.6013.634
313.5469-504B-7-5,3-5509IgneousCurie temperature is from the cooling curve430
314.2169-504B-7-5,71-0515Igneous1.9208.06.827.1003700.930010.6PLAG-OL PHYRIC BASALT,ALT FRESH
316.6369-504B-8-1,12-14520Igneous1.710-5.80-48.610.018.103.0003901.870010.40MASSIVE CHROMITE-BEARING PLAG-OL BASALTS,ALT
316.6369-504B-8-1,12-14520IgneousMOD
317.1069-504B-8-1,59-61523Igneous1.600-12.07.518.853.200Curie temperature is from the cooling curve500MASSIVE CHROMITE BEARING PLAG-OL BASALT,ALT MOD
317.1069-504B-8-1,59-61523IgneousCurie temperature is from the heating curve525
317.1069-504B-8-1,59-61523IgneousCurie temperature is from the heating curve3000.49800.079005.8010.6113
317.2869-504B-8-1,78-0524Igneous2.0508.146.3003500.86909.5APHYRIC BASALT,ALT MOD
318.6269-504B-8-2,60-63529Igneous2.54033.0030.46.017.345.0003402.29008.40MASSIVE CHROMITE-BEARING PLAG-OL BASALTS,ALT
318.6269-504B-8-2,60-63529IgneousSLIGHT
318.8769-504B-8-2,86-88530Igneous6.200-6.011.020.1111.000Curie temperature is from the heating curve3000.70800.999004.309.0120MASSIVE CHROMITE BEARING PLAG-OL BASALT,ALT
318.8769-504B-8-2,86-88530IgneousCurie temperature is from the heating curve460
318.8769-504B-8-2,86-88530IgneousCurie temperature is from the cooling curve285FRESH
319.0969-504B-8-2,109-0532Igneous0.62017.04.893.2003700.771011.7APHYRIC BASALT,ALT FRESH
320.2469-504B-8-3,73-75540Igneous4.200-7.011.520.118.000Curie temperature is from the heating curve3050.68700.120005.409.5MASSIVE CHROMITE BEARING PLAG-OL BASALT,ALT MOD
320.2469-504B-8-3,73-75540IgneousCurie temperature is from the cooling curve505
320.2469-504B-8-3,73-75540IgneousCurie temperature is from the cooling curve500
320.9469-504B-8-3,143-145544Igneous1.72067.7062.410.016.593.0004802.060011.30MASSIVE CHROMITE-BEARING PLAG-OL BASALTS,ALT
320.9469-504B-8-3,143-145544IgneousMOD
321.5969-504B-8-4,58-60553Igneous5.4000.411.017.5911.0000.69800.175007.2012.8100MASSIVE CHROMITE BEARING PLAG-OL BASALT,ALT
321.5969-504B-8-4,58-60553IgneousFRESH
326.0269-504B-9-1,51-53573Igneous28.800-14.020.010.05100.000Curie temperature is from the cooling curve190OL-PLAG MOD PHYRIC BASALT,ALT FRESH TO MOD
326.0269-504B-9-1,51-53573IgneousCurie temperature is from the heating curve2500.54700.2560014.2019.07
327.7469-504B-9-2,73-75597Igneous3.100-15.013.018.856.000Curie temperature is from the cooling curve455APHYRIC TO OL-PLAG SPARSELY PHYRIC BASALT,ALT
327.7469-504B-9-2,73-75597IgneousCurie temperature is from the heating curve3250.49000.109006.4011.2
327.7469-504B-9-2,73-75597IgneousCurie temperature is from the heating curve515FRESH
327.9369-504B-9-2,93-0598Igneous6.3202.7059.2003700.402021.6APHYRIC TO PLAG-OL SPARSELY PHYRIC BASALT,ALT
327.9369-504B-9-2,93-0598IgneousFRESH
336.1269-504B-10-2,11-13628Igneous3.000-41.014.018.856.000Curie temperature is from the cooling curve455APHYRIC TO PLAG-OL PHYRIC PILLOW BASALT,ALT MOD
336.1269-504B-10-2,11-13628IgneousCurie temperature is from the heating curve3300.49200.130006.3012.27
336.1269-504B-10-2,11-13628IgneousCurie temperature is from the heating curve515
338.5969-504B-10-3,109-0657Igneous1.50037.51.7521.60061.4APHYRIC TO PLAG-OL SPARSELY PHYRIC BASALT,ALT
338.5969-504B-10-3,109-0657IgneousFRESH
343.7069-504B-11-1,19-21663Igneous0.500-30.018.012.571.300Curie temperature is from the heating curve505PLAG-OL SPARSELY PHYRIC PILLOW BASALT,ALT MOD
343.7069-504B-11-1,19-21663IgneousCurie temperature is from the heating curve3350.35000.085008.1016.515
343.7069-504B-11-1,19-21663IgneousCurie temperature is from the cooling curve340
345.0269-504B-11-2,2-0680Igneous3.8105.1818.5003900.807018.0PLAG-OL SPARSELY PHYRIC BASALT, ALT EXT
345.7769-504B-11-2,76-78688Igneous0.800-32.016.013.822.100Curie temperature is from the cooling curve510PLAG-OL SPARSELY PHYRIC PILLOW BASALT,ALT MOD
345.7769-504B-11-2,76-78688IgneousCurie temperature is from the heating curve530
345.7769-504B-11-2,76-78688IgneousCurie temperature is from the heating curve3051.2
346.7869-504B-11-3,27-29697Igneous0.80032.017.012.572.400Curie temperature is from the cooling curve305PLAG-OL SPARSELY PHYRIC PILLOW BASALT,ALT MOD,
346.7869-504B-11-3,27-29697IgneousCurie temperature is from the heating curve505
346.7869-504B-11-3,27-29697IgneousCurie temperature is from the heating curve3400.27600.072008.6015.27STABLE INC?
353.0169-504B-12-1,50-52715Igneous2.100-31.016.016.344.700Curie temperature is from the heating curve510PLAG-OL SPARSELY PHYRIC BASALT,ALT MOD
353.0169-504B-12-1,50-52715IgneousCurie temperature is from the heating curve3151.0
353.0169-504B-12-1,50-52715IgneousCurie temperature is from the cooling curve510
354.3369-504B-12-2,33-0731Igneous4.54017.54.9023.3003700.663022.6PLAG-OL SPARSELY MICROPHYRIC BASALT,ALT MOD
355.0869-504B-12-2,107-109743Igneous1.000-29.017.017.592.100Curie temperature is from the cooling curve275PLAG-OL SPARSELY PHYRIC BASALT,ALT FRESH
355.0869-504B-12-2,107-109743IgneousCurie temperature is from the heating curve490
355.0869-504B-12-2,107-109743IgneousCurie temperature is from the heating curve3250.44400.098007.6014.8
362.9169-504B-13-1,140-142765Igneous0.800-19.018.015.082.000Curie temperature is from the heating curve3250.36800.076007.2013.0APHYRIC BASALT PILLOWS,ALT MOD
362.9169-504B-13-1,140-142765IgneousCurie temperature is from the cooling curve180
362.9169-504B-13-1,140-142765IgneousCurie temperature is from the heating curve465
363.9369-504B-13-2,90-95780Igneous2.540-11.700.27.518.354.0003701.51009.90APHYRIC BASALT,ALT MOD
364.0169-504B-13-2,100-102781Igneous2.000-21.017.594.000Curie temperature is from the cooling curve485APHYRIC BASALT PILLOWS,ALT MOD
364.0169-504B-13-2,100-102781IgneousCurie temperature is from the heating curve540
364.0169-504B-13-2,100-102781IgneousCurie temperature is from the heating curve305
365.0369-504B-13-3,51-54790Igneous4.450-41.60-41.410.019.607.0004352.240011.90APHYRIC BASALT,ALT MOD
365.2269-504B-13-3,71-73792Igneous4.500-31.014.022.627.000Curie temperature is from the heating curve490APHYRIC BASALT PILLOWS,ALT MOD
365.2269-504B-13-3,71-73792IgneousCurie temperature is from the heating curve3100.64800.165008.0014.0
365.2269-504B-13-3,71-73792IgneousCurie temperature is from the cooling curve280
366.1069-504B-13-4,10-0802Igneous2.51010.226.2003650.843010.0APHYRIC BASALT,ALT MOD
366.1669-504B-13-4,15-17803Igneous4.100-30.08.020.118.000Curie temperature is from the cooling curve200APHYRIC BASALT PILLOWS,ALT MOD
366.1669-504B-13-4,15-17803IgneousCurie temperature is from the heating curve460
366.1669-504B-13-4,15-17803IgneousCurie temperature is from the heating curve3100.56400.100004.908.017
366.6769-504B-13-4,65-68810Igneous1.78035.6027.69.517.343.0004302.010011.20APHYRIC BASALT,ALT MOD
367.4569-504B-13-4,145-0818Igneous1.32012.08.803.7003800.739013.0APHYRIC BASALT,ALT MOD
370.9069-504B-14-1,39-41841Igneous7.000-29.016.018.8513.000Curie temperature is from the heating curve3100.67600.1780010.9020.44OL SPARSELY MICROPHYRIC BASALT,ALT FRESH
370.9069-504B-14-1,39-41841IgneousCurie temperature is from the cooling curve340
370.9069-504B-14-1,39-41841IgneousCurie temperature is from the heating curve490
372.9169-504B-14-2,91-0869Igneous9.9103.1978.0003800.599021.2OL SPARSELY MICROPHYRIC BASALT
376.7769-504B-15-2,26-28872Igneous1.200-32.016.016.342.800Curie temperature is from the cooling curve195PLAG-OL SPARSELY MICROPHYRIC BASALT PILLOWS,ALT
376.7769-504B-15-2,26-28872IgneousCurie temperature is from the heating curve3300.41600.089005.2014.05
376.7769-504B-15-2,26-28872IgneousCurie temperature is from the heating curve480EXT
379.3969-504B-15-3,138-140920Igneous1.700-24.015.021.362.800Curie temperature is from the cooling curve240PLAG-OL SPARSELY MICROPHYRIC PILLOW BASALT,ALT
379.3969-504B-15-3,138-140920IgneousCurie temperature is from the heating curve3400.35600.072007.2015.68
379.3969-504B-15-3,138-140920IgneousCurie temperature is from the heating curve490FRESH
380.2369-504B-15-4,73-0934Igneous8.00019.53.1265.0003750.396023.5PLAG-OL SPARSELY MICROPHYRIC BASALT,ALT FRESH
380.8069-504B-15-4,129-131941Igneous5.700-31.018.016.3412.000Curie temperature is from the cooling curve355PLAG-OL SPARSELY PHYRIC PILLOW BASALT,ALT
380.8069-504B-15-4,129-131941IgneousCurie temperature is from the heating curve470
380.8069-504B-15-4,129-131941IgneousCurie temperature is from the heating curve3450.56000.1690011.8019.5FRESH
381.5369-504B-15-5,52-54941Igneous2.600-23.012.521.364.600Curie temperature is from the cooling curve455PLAG-OL SPARSELY MICROPHYRIC PILLOW BASALT,ALT
381.5369-504B-15-5,52-54941IgneousCurie temperature is from the heating curve3350.49400.104006.6012.060
381.5369-504B-15-5,52-54941IgneousCurie temperature is from the heating curve500FRESH
381.8769-504B-15-5,87-0954Igneous1.13011.510.052.8003650.803012.3PLAG-OL SPARSELY MICROPHYRIC BASALT,ALT FRESH
384.2169-504B-16-1,20-22958Igneous2.200-24.013.020.114.000Curie temperature is from the cooling curve475PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT MOD
384.2169-504B-16-1,20-22958IgneousCurie temperature is from the heating curve530
384.2169-504B-16-1,20-22958IgneousCurie temperature is from the heating curve3200.68000.159008.2014.016
384.7269-504B-16-1,70-73964Igneous2.180-1.50-1.612.817.094.0002.82009.60PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT MOD
385.5769-504B-16-2,6-8975Igneous0.800-30.018.020.111.500Curie temperature is from the heating curve480PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT MOD
385.5769-504B-16-2,6-8975IgneousCurie temperature is from the heating curve3150.64000.120005.9011.016
385.5769-504B-16-2,6-8975IgneousCurie temperature is from the cooling curve480
385.7569-504B-16-2,25-0976Igneous1.8707.546.2003600.882012.9PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT MOD
386.3269-504B-16-2,81-83981Igneous2.680-50.50-30.86.520.364.0004252.490010.20PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT MOD
387.2669-504B-16-3,25-27990Igneous0.98047.0031.311.525.011.0004352.14009.20PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT FRESH
387.5269-504B-16-3,52-0993Igneous3.6409.809.3003801.044013.0PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT FRESH
387.6769-504B-16-3,66-68994Igneous0.200-34.024.025.130.600Curie temperature is from the heating curve520PLAG-OL-CPX SPARSELY PHYRIC BASALT,ALT FRESH
387.6769-504B-16-3,66-68994IgneousCurie temperature is from the heating curve350
387.6769-504B-16-3,66-68994IgneousCurie temperature is from the cooling curve500
388.3569-504B-16-3,134-136Igneous6.500-40.015.017.5913.000Curie temperature is from the cooling curve280PLAG-OL PHYRIC PILLOW BASALT,ALT FRESH,PCE
388.3569-504B-16-3,134-136IgneousCurie temperature is from the heating curve440
388.3569-504B-16-3,134-136IgneousCurie temperature is from the heating curve3100.52600.1750010.0015.0NUMBER=1001
388.8569-504B-16-4,35-0Igneous2.90028.02.2632.2003950.237029.8PLAG-OL PHYRIC BASALT,ALT MOD,PCE NUMBER=1006
389.0469-504B-16-4,54-0Igneous4.6503.9529.6004000.458018.5PLAG-OL PHYRIC BASALT,ALT MOD,PCE NUMBER=1008
389.5669-504B-16-4,105-107Igneous7.000-27.011.3121.000Curie temperature is from the cooling curve270PLAG-OL PHYRIC PILLOW BASALT,ALT MOD,PCE NUMBER=
389.5669-504B-16-4,105-107IgneousCurie temperature is from the heating curve335
389.5669-504B-16-4,105-107IgneousCurie temperature is from the heating curve4851013
393.0269-504B-17-1,2-0Igneous5.88019.05.5326.7000.528023.4PLAG-OL MOD PHYRIC TO PHYRIC BASALT,ALT FRESH,
393.0269-504B-17-1,2-0IgneousPCE NUMBER=1034
393.9769-504B-17-1,96-98Igneous4.700-12.016.018.859.000Curie temperature is from the heating curve3100.50600.135009.8017.0PLAG-OL PHYRIC TO MOD PHYRIC BASALT,ALT SLIGHT TO
393.9769-504B-17-1,96-98IgneousCurie temperature is from the heating curve500
393.9769-504B-17-1,96-98IgneousCurie temperature is from the cooling curve465MOD,PCE NUMBER=1044
395.2269-504B-17-2,72-0Igneous2.6006.5310.0003600.538018.5PLAG-OL MOD PHYRIC TO PHYRIC BASALT,ALT FRESH,
395.2269-504B-17-2,72-0IgneousPCE NUMBER=1062
395.5569-504B-17-2,104-106Igneous6.50017.014.517.5913.000Curie temperature is from the heating curve500PLAG-OL PHYRIC TO MOD PHYRIC BASALT,ALT SLIGHT TO
395.5569-504B-17-2,104-106IgneousCurie temperature is from the cooling curve450
395.5569-504B-17-2,104-106IgneousCurie temperature is from the heating curve31518MOD,PCE NUMBER=1065,ST INC?
398.7269-504B-18-1,71-73Igneous13.800-23.011.017.5928.000Curie temperature is from the heating curve3100.57000.143008.7015.510PLAG-OL SPARSELY PHYRIC BASALT,ALT MOD,PCE
398.7269-504B-18-1,71-73IgneousCurie temperature is from the heating curve485
398.7269-504B-18-1,71-73IgneousCurie temperature is from the cooling curve225NUMBER=1090
399.5469-504B-18-2,4-0Igneous5.25015.03.5936.7003600.566018.5PLAG-OL SPARSELY PHYRIC BASALT,ALT FRESH,PCE
399.5469-504B-18-2,4-0IgneousNUMBER=1100
404.0269-504B-19-1,101-103Igneous7.000-25.021.07.5433.000Curie temperature is from the heating curve480PLAG-OL SPARSELY PHYRIC BASALT,ALT MOD,PCE
404.0269-504B-19-1,101-103IgneousCurie temperature is from the cooling curve410
404.0269-504B-19-1,101-103IgneousCurie temperature is from the heating curve3050.39800.1840014.9021.55NUMBER=1126
405.3769-504B-19-2,86-88Igneous2.800-10.012.520.115.000Curie temperature is from the cooling curve485PLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD,PCE NUMBER
405.3769-504B-19-2,86-88IgneousCurie temperature is from the heating curve510
405.3769-504B-19-2,86-88IgneousCurie temperature is from the heating curve3100.62800.152008.4015.071145
405.5669-504B-19-2,106-0Igneous4.6608.4813.8003600.442021.3PLAG-OL-CPX PHYRIC BASALT,ALT MOD,PCE NUMBER=
405.5669-504B-19-2,106-0Igneous1149
412.8469-504B-20-1,84-0Igneous1.37014.57.544.6003600.835010.2PLAG MOD PHYRIC BASALT,ALT MOD,PCE NUMBER=1170
413.1069-504B-20-1,109-111Igneous2.500-31.010.518.854.500Curie temperature is from the heating curve505PLAG MOD PHYRIC BASALT,ALT MOD,PCE NUMBER=1173
413.1069-504B-20-1,109-111IgneousCurie temperature is from the heating curve3150.76200.116004.809.340
413.1069-504B-20-1,109-111IgneousCurie temperature is from the cooling curve530
421.3069-504B-21-1,30-0Volcanic breccia (igneous)5.1000.65196.0003950.433029.5BRECCIA,ALT SLIGHTLY,PCE NUMBER=1182
422.3869-504B-21-1,137-139Igneous2.100-34.014.521.363.400Curie temperature is from the heating curve520PLAG MOD PHYRIC BASALT,ALT MOD TO EXT,PCE NUMBER
422.3869-504B-21-1,137-139IgneousCurie temperature is from the cooling curve5101196
422.3969-504B-21-1,137-140Igneous2.10014.521.87Curie temperature is from the heating curve3200.78200.120005.2011.052PLAG MOD PHYRIC BASALT,ALT MOD TO EXT,PCE NUMBER
422.3969-504B-21-1,137-140Igneous1196
423.1069-504B-21-2,59-61Igneous10.800-28.016.3424.000Curie temperature is from the heating curve470PLAG-OL PHYRIC BASALT,ALT SLIGHT,PCE NUMBER=1208
423.1069-504B-21-2,59-61IgneousCurie temperature is from the heating curve450
423.1069-504B-21-2,59-61IgneousCurie temperature is from the cooling curve220
423.5469-504B-21-2,104-0Igneous4.40014.54.7823.2003800.720015.2PLAG-OL MOD PHYRIC TO PHYRIC BASALT,ALT SLIGHTLY,
423.5469-504B-21-2,104-0IgneousPCE NUMBER=1213
424.1269-504B-21-3,12-0Igneous1.7401.0342.4000.241040.5PLAG-OL MOD PHYRIC TO PHYRIC BASALT,ALT FRESH,
424.1269-504B-21-3,12-0IgneousPCE NUMBER=1220
425.2469-504B-21-3,123-125Igneous3.500-29.09.021.366.000Curie temperature is from the cooling curve505PLAG-OL SPARSELY PHYRIC BASALT,ALT MOD,PCE
425.2469-504B-21-3,123-125IgneousCurie temperature is from the heating curve31022
425.2469-504B-21-3,123-125IgneousCurie temperature is from the heating curve530NUMBER=1234
425.5369-504B-21-4,3-0Igneous4.4009.06.5317.0003800.769012.0APHYRIC TO PLAG-OL PHYRIC BASALT,ALT MOD,PCE
425.5369-504B-21-4,3-0IgneousNUMBER=1237
426.8769-504B-21-4,136-138Igneous3.700-26.017.021.366.000Curie temperature is from the cooling curve395PLAG-OL MOD PHYRIC BASALT,ALT FRESH,PCE NUMBER=
426.8769-504B-21-4,136-138IgneousCurie temperature is from the heating curve3500.57600.1430010.5019.824
426.8769-504B-21-4,136-138IgneousCurie temperature is from the heating curve4951256
427.0369-504B-21-5,3-0Igneous2.16017.52.2923.7004000.310022.9PLAG-OL MOD PHYRIC BASALT,ALT FRESH,PCE NUMBER=
427.0369-504B-21-5,3-0Igneous1259
430.3469-504B-22-1,34-0Igneous4.6103.9629.3003900.645022.5PLAG-OL-CPX PHYRIC BASALT,ALT FRESH,PCE NUMBER=
430.3469-504B-22-1,34-0Igneous1272
430.6369-504B-22-1,62-64Igneous4.300-27.037.08.8018.000Curie temperature is from the cooling curve370PLAG-OL-CPX PHYRIC BASALT,PCE NUMBER=1275
430.6369-504B-22-1,62-64IgneousCurie temperature is from the heating curve420
430.6369-504B-22-1,62-64IgneousCurie temperature is from the heating curve3900.32200.1440023.2040.04
439.8969-504B-23-1,88-90Igneous4.900-40.016.020.118.000Curie temperature is from the heating curve3300.62600.1460010.4017.25PLAG-OL-CPX PHYRIC PILLOW BASALT,ALT MOD,PCE
439.8969-504B-23-1,88-90IgneousCurie temperature is from the heating curve495
439.8969-504B-23-1,88-90IgneousCurie temperature is from the cooling curve475NUMBER=1322
440.1369-504B-23-1,113-0Igneous3.68014.07.9211.7003800.954017.4PLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD,PCE
440.1369-504B-23-1,113-0IgneousNUMBER=1326
448.8869-504B-24-1,88-0Igneous5.3304.0233.3004000.484022.5PLAG-OL-CPX PHYRIC BASALT,ALT MOD,PCE NUMBER=
448.8869-504B-24-1,88-0Igneous1343
449.0169-504B-24-1,100-102Igneous6.500-29.017.013.8216.000Curie temperature is from the heating curve480PLAG-OL-CPX PHYRIC PILLOW BASALT,ALT MOD,PCE
449.0169-504B-24-1,100-102IgneousCurie temperature is from the cooling curve360
449.0169-504B-24-1,100-102IgneousCurie temperature is from the heating curve3350.30200.1030013.6023.06NUMBER=1344
450.1369-504B-24-2,62-64Igneous6.300-36.018.011.3120.000PLAG-OL-CPX PHYRIC PILLOW BASALT,ALT MOD,PCE
450.1369-504B-24-2,62-64IgneousNUMBER=1361
450.7569-504B-24-2,123-126Igneous2.260-0.401.79.020.614.0004501.760010.30PLAG-OL-CPX PHYRIC BASALT,ALT MOD,PCE NUMBER=
450.7569-504B-24-2,123-126Igneous1371
451.7769-504B-24-3,76-78Igneous5.800-29.018.016.3413.000Curie temperature is from the cooling curve405PLAG-OL-CPX PHYRIC PILLOW BASALT,ALT MOD,PCE
451.7769-504B-24-3,76-78IgneousCurie temperature is from the heating curve3400.51200.1490012.6021.09
451.7769-504B-24-3,76-78IgneousCurie temperature is from the heating curve490NUMBER=1386
451.8369-504B-24-3,81-84Igneous7.390-46.90-43.514.514.4516.0001.910015.50PLAG-OL-CPX PHYRIC BASALT,ALT MOD,PCE NUMBER=
451.8369-504B-24-3,81-84Igneous1387
457.3469-504B-25-1,34-0Igneous6.56015.52.6861.3003900.475021.2APHYRIC OR PLAG-OL SPARSELY PHYRIC BASALT,ALT
457.3469-504B-25-1,34-0IgneousMOD,PCE NUMBER=1402
458.6169-504B-25-2,9-13Igneous1.490-44.20-39.79.221.872.0004452.200010.80PHYRIC OR OL-PLAG VERY SPARSELY PHYRIC BASALT,
458.6169-504B-25-2,9-13IgneousALT SLIGHT,PCE NUMBER=1421
459.3469-504B-25-2,83-85Igneous0.700-25.011.030.160.900Curie temperature is from the cooling curve470APHYRIC OR OL-PLAG VERY SPARSELY PHYRIC BASALT,
459.3469-504B-25-2,83-85IgneousCurie temperature is from the heating curve3650.64000.095005.8013.015
459.3469-504B-25-2,83-85IgneousCurie temperature is from the heating curve510ALT SLIGHT,PCE NUMBER=1431
459.6369-504B-25-2,113-0Igneous4.0000.75133.0000.298028.9APHYRIC OR PLAG-OL SPARSELY PHYRIC BASALT,ALT
459.6369-504B-25-2,113-0IgneousFRESH,PCE NUMBER=1436
463.0369-504B-26-1,3-0Igneous1.7109.514.203.0003851.220012.0APHYRIC BASALT,ALT MOD,PCE NUMBER=1447
467.1069-504B-27-1,109-111Igneous0.900-7.08.530.161.100Curie temperature is from the heating curve520APHYRIC BASALT,ALT MOD,PCE NUMBER=1473
467.1069-504B-27-1,109-111IgneousCurie temperature is from the heating curve3450.71600.097004.7010.533
467.1069-504B-27-1,109-111IgneousCurie temperature is from the cooling curve495
467.5769-504B-27-2,6-8Igneous4.500-16.020.012.5714.000Curie temperature is from the cooling curve190PLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER=
467.5769-504B-27-2,6-8IgneousCurie temperature is from the heating curve4851478
475.0769-504B-28-1,5-8Igneous3.79059.6060.413.013.329.0003651.680014.20PLAG-OL SPARSELY PHYRIC BASALT,ALT MOD,PCE
475.0769-504B-28-1,5-8IgneousNUMBER=1487
475.3269-504B-28-1,32-0Igneous0.96030.02.898.3005200.154040.8PLAG-OL SPARSELY PHYRIC BASALT,ALT MOD,PCE
475.3269-504B-28-1,32-0IgneousNUMBER=1490
475.9069-504B-28-1,90-0Igneous1.85014.833.1003651.12606.7PLAG-OL-CPX PHYRIC BASALT,ALT FRESH,PCE NUMBER=
475.9069-504B-28-1,90-0Igneous1496
475.9669-504B-28-1,95-97Igneous3.300-10.06.028.904.300Curie temperature is from the cooling curve435PLAG-OL-CPX PHYRIC TO MOD PHYRIC BASALT,ALT
475.9669-504B-28-1,95-97IgneousCurie temperature is from the heating curve3250.95400.171003.407.550
475.9669-504B-28-1,95-97IgneousCurie temperature is from the heating curve445FRESH,PCE NUMBER=1496
478.4769-504B-28-3,45-48Igneous3.110-28.70-44.612.019.105.0004001.980014.60PLAG-OL-CPX PHYRIC TO MOD PHYRIC BASALT,ALT
478.4769-504B-28-3,45-48IgneousSLIGHT TO MOD,PCE NUMBER=1527
478.5769-504B-28-3,56-58Igneous4.400-46.016.021.368.000Curie temperature is from the cooling curve335PLAG-OL-CPX PHYRIC TO MOD PHYRIC BASALT,ALT
478.5769-504B-28-3,56-58IgneousCurie temperature is from the heating curve475
478.5769-504B-28-3,56-58IgneousCurie temperature is from the heating curve3400.55600.1620011.0019.08SLIGHT TO MOD,PCE NUMBER=1528
478.9369-504B-28-3,93-0Igneous2.0008.176.2003900.884013.2PLAG-OL-CPX PHYRIC BASALT,ALT FRESH,PCE NUMBER=
478.9369-504B-28-3,93-0Igneous1533
479.6569-504B-28-4,15-0Igneous2.47027.00.8474.8004000.276036.5PLAG-OL-CPX PHYRIC BASALT,ALT FRESH,PCE NUMBER=
479.6569-504B-28-4,15-0Igneous1541
480.7469-504B-28-4,123-125Igneous0.400-43.020.033.930.400Curie temperature is from the heating curve525PLAG-OL-CPX PHYRIC TO MOD PHYRIC BASALT,ALT
480.7469-504B-28-4,123-125IgneousCurie temperature is from the cooling curve505
480.7469-504B-28-4,123-125IgneousCurie temperature is from the heating curve3600.82400.138005.4011.5SLIGHT TO MOD,PCE NUMBER=1553
481.1869-504B-28-5,16-19Igneous1.7407.7023.79.521.613.0003702.48008.80PLAG-OL-CPX PHYRIC TO MOD PHYRIC BASALT,ALT
481.1869-504B-28-5,16-19IgneousSLIGHT TO MOD,PCE NUMBER=1558
484.0569-504B-29-1,4-6Igneous6.200-20.014.016.3414.000Curie temperature is from the cooling curve530APHYRIC BASALT,ALT MOD,PCE NUMBER=1559
484.0569-504B-29-1,4-6IgneousCurie temperature is from the heating curve3500.43200.129008.8015.6
484.0569-504B-29-1,4-6IgneousCurie temperature is from the heating curve510
484.2769-504B-29-1,27-0Igneous5.7402.4559.0004000.608019.2APHYRIC BASALT,ALT FRESH,PCE NUMBER=1561