Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Wefer, Gerold; Berger, Wolfgang H; Richter, Carl; Shipboard Scientific Party (2005): Results of rock eval carbon analysis on ODP Hole 175-1081A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.259439

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
ODP/TAMU (2005): JANUS Database. Ocean Drilling Program, Texas A&M University, College Station TX 77845-9547, USA; (data copied from Janus 2005-02 to 2005-06), http://www-odp.tamu.edu/database/
Wefer, Gerold; Berger, Wolfgang H; Richter, C; et al. (1998): Proceedings of the Ocean Drilling Program 175 Initial Reports. Proceedings of the Ocean Drilling Program, Ocean Drilling Program, 175, online, https://doi.org/10.2973/odp.proc.ir.175.1998
Project(s):
Coverage:
Latitude: -19.619690 * Longitude: 11.319300
Date/Time Start: 1997-09-09T02:00:00 * Date/Time End: 1997-09-11T21:15:00
Minimum DEPTH, sediment/rock: 0.470 m * Maximum DEPTH, sediment/rock: 443.950 m
Event(s):
175-1081A * Latitude: -19.619690 * Longitude: 11.319300 * Date/Time Start: 1997-09-09T02:00:00 * Date/Time End: 1997-09-11T21:15:00 * Elevation: -794.1 m * Penetration: 452.7 m * Recovery: 393.48 m * Location: Benguela Current, South Atlantic Ocean * Campaign: Leg175 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 49 cores; 452.7 m cored; 0 m drilled; 86.9 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Depth, compositeDepth compmcdShipboard Scientific Party
Sample code/labelSample labelShipboard Scientific PartyDSDP/ODP/IODP sample designation
Carbon, totalTC%Shipboard Scientific PartyRock eval pyrolysis (Behar et al., 2001)
Hydrocarbon yield, S1 per unit sediment massS1 HC/sedmg/gShipboard Scientific PartyRock eval pyrolysis (Behar et al., 2001)
Hydrocarbon yield, S2 per unit sediment massS2 HC/sedmg/gShipboard Scientific PartyRock eval pyrolysis (Behar et al., 2001)
Carbon dioxide yield, S3 per unit sediment massS3 CO2/sedmg/gShipboard Scientific PartyRock eval pyrolysis (Behar et al., 2001)
Pyrolysis temperature maximumTmax°CShipboard Scientific PartyRock eval pyrolysis (Behar et al., 2001)
Oxygen index, mass CO2, per unit mass total organic carbonOI, CO2/TOCmg/gShipboard Scientific PartyRock eval pyrolysis (Behar et al., 2001)
10 Hydrogen index, mass HC, per unit mass total organic carbonHI, HC/TOCmg/gShipboard Scientific PartyRock eval pyrolysis (Behar et al., 2001)
Size:
261 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Depth comp [mcd]

Sample label

TC [%]

S1 HC/sed [mg/g]

S2 HC/sed [mg/g]

S3 CO2/sed [mg/g]

Tmax [°C]

OI, CO2/TOC [mg/g]
10 
HI, HC/TOC [mg/g]
0.4700.470175-1081A-1H-1,47-484.0501.78015.6604.60041723386
1.4602.870175-1081A-2H-1,46-475.1703.10023.4904.900411113454
4.4605.870175-1081A-2H-3,46-477.8608.13032.5405.63040594413
5.9607.370175-1081A-2H-4,46-475.0802.19019.6604.53041171387
31.46036.730175-1081A-5H-2,46-473.0600.6409.7003.10041589316
37.36042.630175-1081A-5H-6,46-477.1101.90031.0704.770413101436
61.46068.330175-1081A-8H-3,46-472.8900.6709.9002.93041267342
64.36071.230175-1081A-8H-5,46-474.4001.03015.6803.680418101356
67.96075.950175-1081A-9H-1,46-476.5301.62027.9904.75041683428
70.96078.950175-1081A-9H-3,46-474.6400.96017.0505.48041472367
73.86081.850175-1081A-9H-5,46-474.4001.10017.0004.180413118386
77.46087.430175-1081A-10H-1,46-477.0602.59031.8904.59040195451
80.46090.430175-1081A-10H-3,46-474.2100.88015.3804.60041565365
81.86091.830175-1081A-10H-4,46-473.5800.71012.7704.000415109356
96.460105.940175-1081A-12H-1,46-477.3703.44033.1405.130391111449
118.460130.960175-1081A-14H-3,46-475.8502.28024.8804.41039469425
121.460133.960175-1081A-14H-5,46-478.0902.40034.3605.92039375424
124.960137.500175-1081A-15H-1,46-474.8701.38018.7705.42040173385
137.400149.940175-1081A-17X-1,40-418.2104.04033.6405.700392111409
152.410165.450175-1081A-18H-5,46-474.9001.81017.4605.21040369356
154.960168.040175-1081A-19X-1,46-475.3302.14020.0805.840401106376
157.960171.040175-1081A-19X-3,46-474.9901.77010.2305.860396109205
164.560177.640175-1081A-20X-1,46-474.2801.06012.3102.63040461287
193.550206.630175-1081A-23X-1,45-467.3402.03027.3305.16040270372
212.850225.390175-1081A-25X-1,45-464.5200.71013.9305.630427124308
272.110284.650175-1081A-31X-2,51-526.1800.92021.4904.75041476347
357.430369.970175-1081A-40X-1,63-641.3700.2102.8903.340421243210
415.100427.640175-1081A-46X-1,50-511.5100.3103.3503.960415262221
443.950456.490175-1081A-49X-1,45-472.2000.3703.9003.160416143177