Exon, Neville F; Kennett, James P; Malone, Mitchell J; Shipboard Scientific Party (2005): Gas elements of ODP Hole 189-1172A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.257312
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Exon, Neville F; Kennett, James P; Malone, Mitchell J; et al. (2001): Proceedings of the Ocean Drilling Program, 189 Initial Reports. Proceedings of the Ocean Drilling Program, Ocean Drilling Program, 189, online, https://doi.org/10.2973/odp.proc.ir.189.2001
ODP/TAMU (2005): JANUS Database. Ocean Drilling Program, Texas A&M University, College Station TX 77845-9547, USA; (data copied from Janus 2005-02 to 2005-06), http://www-odp.tamu.edu/database/
Further details:
Pimmel, Anne; Claypool, George E (2001): Introduction to shipboard organic geochemistry on the JOIDES resolution. Ocean Drilling Program Technical Notes, Ocean Drilling Program, https://doi.org/10.2973/odp.tn.30.2001
Project(s):
Ocean Drilling Program (ODP)
Coverage:
Latitude: -43.959750 * Longitude: 149.928260
Date/Time Start: 2000-04-22T06:45:00 * Date/Time End: 2000-04-26T09:30:00
Minimum DEPTH, sediment/rock: 4.50 m * Maximum DEPTH, sediment/rock: 518.00 m
Event(s):
189-1172A * Latitude: -43.959750 * Longitude: 149.928260 * Date/Time Start: 2000-04-22T06:45:00 * Date/Time End: 2000-04-26T09:30:00 * Elevation: -2621.9 m * Penetration: 522.6 m * Recovery: 483.72 m * Location: Tasman Sea * Campaign: Leg189 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 56 cores; 522.6 m cored; 0 m drilled; 92.6 % recovery
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
2 | Depth, composite | Depth comp | mcd | Shipboard Scientific Party | ||
3 | Sample code/label | Sample label | Shipboard Scientific Party | DSDP/ODP/IODP sample designation | ||
4 | Methane/ethane ratio | C1/C2 | Shipboard Scientific Party | |||
5 | Methane | CH4 | ppmv | Shipboard Scientific Party | ||
6 | Ethane | C2H6 | ppmv | Shipboard Scientific Party | ||
7 | Ethene | C2H4 | ppmv | Shipboard Scientific Party | ||
8 | Propane | C3H8 | ppmv | Shipboard Scientific Party | ||
9 | Propene | C3H6 | ppmv | Shipboard Scientific Party | ||
10 | Run ID | Run ID | Shipboard Scientific Party | |||
11 | Instrument | Instrument | Shipboard Scientific Party | |||
12 | Method comment | Method comm | Shipboard Scientific Party | |||
13 | Detector | Detector | Shipboard Scientific Party |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
595 data points
Data
1 Depth sed [m] | 2 Depth comp [mcd] | 3 Sample label | 4 C1/C2 | 5 CH4 [ppmv] | 6 C2H6 [ppmv] | 7 C2H4 [ppmv] | 8 C3H8 [ppmv] | 9 C3H6 [ppmv] | 10 Run ID | 11 Instrument | 12 Method comm | 13 Detector |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4.50 | 4.82 | 189-1172A-1H-4,0-5 | 1.90 | 0.00 | 0.00 | 0.00 | 0.00 | 84830 | GC3 | HS | FID | |
10.80 | 11.72 | 189-1172A-2H-4,0-5 | 2.20 | 0.00 | 0.00 | 0.00 | 0.00 | 84835 | GC3 | HS | FID | |
20.30 | 22.52 | 189-1172A-3H-4,0-5 | 2.20 | 0.00 | 0.00 | 0.00 | 0.00 | 84840 | GC3 | HS | FID | |
29.80 | 31.72 | 189-1172A-4H-4,0-5 | 2.50 | 0.00 | 0.00 | 0.00 | 0.00 | 84845 | GC3 | HS | FID | |
39.30 | 42.24 | 189-1172A-5H-4,0-5 | 2.70 | 0.00 | 0.00 | 0.00 | 0.00 | 84850 | GC3 | HS | FID | |
48.80 | 51.74 | 189-1172A-6H-4,0-5 | 1.90 | 0.00 | 0.00 | 0.00 | 0.00 | 84855 | GC3 | HS | FID | |
58.30 | 61.24 | 189-1172A-7H-4,0-5 | 2.40 | 0.00 | 0.00 | 0.00 | 0.00 | 84860 | GC3 | HS | FID | |
67.80 | 70.74 | 189-1172A-8H-4,0-5 | 3.10 | 0.00 | 0.00 | 0.00 | 0.00 | 84865 | GC3 | HS | FID | |
77.30 | 80.24 | 189-1172A-9H-4,0-5 | 2.40 | 0.00 | 0.00 | 0.00 | 0.00 | 84870 | GC3 | HS | FID | |
86.80 | 89.74 | 189-1172A-10H-4,0-5 | 2.80 | 0.00 | 0.00 | 0.00 | 0.00 | 84875 | GC3 | HS | FID | |
96.30 | 106.22 | 189-1172A-11H-4,0-5 | 3.90 | 0.00 | 0.00 | 0.00 | 0.00 | 84880 | GC3 | HS | FID | |
105.80 | 116.80 | 189-1172A-12H-4,0-5 | 4.10 | 0.00 | 0.00 | 0.00 | 0.00 | 84885 | GC3 | HS | FID | |
115.30 | 126.42 | 189-1172A-13H-4,0-5 | 2.70 | 0.00 | 0.00 | 0.00 | 0.00 | 84890 | GC3 | HS | FID | |
124.80 | 135.88 | 189-1172A-14H-4,0-5 | 4.30 | 0.00 | 0.00 | 0.00 | 0.00 | 84895 | GC3 | HS | FID | |
134.30 | 145.38 | 189-1172A-15H-4,0-5 | 2.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84900 | GC3 | HS | FID | |
143.80 | 154.88 | 189-1172A-16H-4,0-5 | 1.80 | 0.00 | 0.00 | 0.00 | 0.00 | 84905 | GC3 | HS | FID | |
153.30 | 164.38 | 189-1172A-17H-4,0-5 | 1.80 | 0.00 | 0.00 | 0.00 | 0.00 | 84910 | GC3 | HS | FID | |
162.80 | 173.88 | 189-1172A-18H-4,0-5 | 1.90 | 0.00 | 0.00 | 0.00 | 0.00 | 84915 | GC3 | HS | FID | |
172.30 | 183.38 | 189-1172A-19H-4,0-5 | 1.80 | 0.00 | 0.00 | 0.00 | 0.00 | 84920 | GC3 | HS | FID | |
181.80 | 192.88 | 189-1172A-20H-4,0-5 | 2.30 | 0.00 | 0.00 | 0.00 | 0.00 | 84925 | GC3 | HS | FID | |
191.30 | 202.38 | 189-1172A-21H-4,0-5 | 12.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84930 | GC3 | HS | FID | |
200.80 | 211.88 | 189-1172A-22H-4,0-5 | 1.90 | 0.00 | 0.00 | 0.00 | 0.00 | 84935 | GC3 | HS | FID | |
210.30 | 221.38 | 189-1172A-23H-4,0-5 | 3.10 | 0.00 | 0.00 | 0.00 | 0.00 | 84940 | GC3 | HS | FID | |
219.80 | 230.88 | 189-1172A-24H-4,0-5 | 2.60 | 0.00 | 0.00 | 0.00 | 0.00 | 84945 | GC3 | HS | FID | |
226.30 | 237.38 | 189-1172A-25X-2,0-5 | 2.40 | 0.00 | 0.00 | 0.00 | 0.00 | 84950 | GC3 | HS | FID | |
233.10 | 244.18 | 189-1172A-26X-3,0-5 | 2.20 | 0.00 | 0.00 | 0.00 | 0.00 | 84955 | GC3 | HS | FID | |
244.20 | 255.28 | 189-1172A-27X-4,0-5 | 2.90 | 0.00 | 0.00 | 0.00 | 0.00 | 84960 | GC3 | HS | FID | |
252.30 | 263.38 | 189-1172A-28X-3,0-5 | 5.20 | 0.00 | 0.00 | 0.00 | 0.00 | 84965 | GC3 | HS | FID | |
263.40 | 274.48 | 189-1172A-29X-4,0-5 | 3.50 | 0.00 | 0.00 | 0.00 | 0.00 | 84970 | GC3 | HS | FID | |
272.50 | 283.58 | 189-1172A-30X-4,0-5 | 2.50 | 0.00 | 0.00 | 0.00 | 0.00 | 84975 | GC3 | HS | FID | |
282.10 | 293.18 | 189-1172A-31X-4,0-5 | 2.70 | 0.00 | 0.00 | 0.00 | 0.00 | 84980 | GC3 | HS | FID | |
291.70 | 302.78 | 189-1172A-32X-4,0-5 | 2.10 | 0.00 | 0.00 | 0.00 | 0.00 | 84985 | GC3 | HS | FID | |
301.30 | 312.38 | 189-1172A-33X-4,0-1 | 2.90 | 0.00 | 0.00 | 0.00 | 0.00 | 84990 | GC3 | HS | FID | |
311.00 | 322.08 | 189-1172A-34X-4,0-1 | 2.40 | 0.00 | 0.00 | 0.00 | 0.00 | 84995 | GC3 | HS | FID | |
320.60 | 331.68 | 189-1172A-35X-4,0-1 | 4.30 | 0.00 | 0.00 | 0.00 | 0.00 | 85000 | GC3 | HS | FID | |
330.20 | 341.28 | 189-1172A-36X-4,0-1 | 4.30 | 0.00 | 0.00 | 0.00 | 0.00 | 85005 | GC3 | HS | FID | |
339.80 | 350.88 | 189-1172A-37X-4,0-1 | 1.90 | 0.00 | 0.00 | 0.00 | 0.00 | 85010 | GC3 | HS | FID | |
349.40 | 360.48 | 189-1172A-38X-4,0-1 | 2.20 | 0.00 | 0.00 | 0.00 | 0.00 | 85015 | GC3 | HS | FID | |
359.10 | 370.94 | 189-1172A-39X-4,0-1 | 9.80 | 0.00 | 0.00 | 0.00 | 0.00 | 85020 | GC3 | HS | FID | |
368.70 | 380.54 | 189-1172A-40X-4,0-1 | 2.20 | 0.00 | 0.00 | 0.00 | 0.00 | 85025 | GC3 | HS | FID | |
378.15 | 389.99 | 189-1172A-41X-4,0-1 | 1.70 | 0.00 | 0.00 | 0.00 | 0.00 | 85030 | GC3 | HS | FID | |
387.90 | 399.74 | 189-1172A-42X-4,0-1 | 1.80 | 0.00 | 0.00 | 0.00 | 0.00 | 85035 | GC3 | HS | FID | |
397.50 | 409.34 | 189-1172A-43X-4,0-1 | 2.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85040 | GC3 | HS | FID | |
407.10 | 418.94 | 189-1172A-44X-4,0-1 | 2.10 | 0.00 | 0.00 | 0.00 | 0.00 | 85045 | GC3 | HS | FID | |
416.70 | 428.54 | 189-1172A-45X-4,0-1 | 2.20 | 0.00 | 0.00 | 0.00 | 0.00 | 85050 | GC3 | HS | FID | |
426.30 | 438.14 | 189-1172A-46X-4,0-1 | 2.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85055 | GC3 | HS | FID | |
435.90 | 447.74 | 189-1172A-47X-4,0-1 | 2.40 | 0.00 | 0.00 | 0.00 | 0.00 | 85060 | GC3 | HS | FID | |
445.50 | 457.34 | 189-1172A-48X-4,0-1 | 8.80 | 0.00 | 0.00 | 0.00 | 0.00 | 85065 | GC3 | HS | FID | |
455.10 | 466.94 | 189-1172A-49X-4,0-1 | 2.20 | 0.00 | 0.00 | 0.00 | 0.00 | 85070 | GC3 | HS | FID | |
474.30 | 486.14 | 189-1172A-51X-4,0-1 | 3.60 | 0.00 | 0.00 | 0.00 | 0.00 | 85075 | GC3 | HS | FID | |
493.50 | 505.34 | 189-1172A-53X-4,0-1 | 5.20 | 0.00 | 0.00 | 0.00 | 0.00 | 85080 | GC3 | HS | FID | |
503.10 | 514.94 | 189-1172A-54X-4,0-1 | 1.33 | 20.50 | 15.40 | 14.50 | 13.70 | 13.70 | 85085 | GC3 | HS | FID |
508.30 | 520.14 | 189-1172A-55X-1,0-1 | 5.10 | 0.00 | 0.00 | 0.00 | 0.00 | 85090 | GC3 | HS | FID | |
518.00 | 529.84 | 189-1172A-56X-CC,0-1 | 3.70 | 0.00 | 0.00 | 0.00 | 0.00 | 85095 | GC3 | HS | FID |