Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Norris, Richard D; Kroon, Dick; Klaus, Adam; Shipboard Scientific Party (2005): Carbonates and bulk sediment geochemistry of ODP Hole 171-1052A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.252297

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Norris, Richard D; Kroon, Dick; Klaus, Adam; et al. (1998): Proceedings of the Ocean Drilling Program 171B Initial Reports. Proceedings of the Ocean Drilling Program, Ocean Drilling Program, 171B, online, https://doi.org/10.2973/odp.proc.ir.171b.1998
ODP/TAMU (2005): JANUS Database. Ocean Drilling Program, Texas A&M University, College Station TX 77845-9547, USA; (data copied from Janus 2005-02 to 2005-06), http://www-odp.tamu.edu/database/
Project(s):
Coverage:
Latitude: 29.951500 * Longitude: -76.626580
Date/Time Start: 1997-01-30T15:00:00 * Date/Time End: 1997-01-30T15:00:00
Minimum DEPTH, sediment/rock: 0.63 m * Maximum DEPTH, sediment/rock: 168.72 m
Event(s):
171-1052A * Latitude: 29.951500 * Longitude: -76.626580 * Date/Time: 1997-01-30T15:00:00 * Elevation: -1344.5 m * Penetration: 174.5 m * Recovery: 159.63 m * Location: Blake Nose, North Atlantic Ocean * Campaign: Leg171B * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 21 core; 174.5 m cored; 0 m drilled; 91.5 % recovery
Comment:
Data derive from coulometer, CHNS analyzer, and pyrolysis oven (rock eval)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Depth, compositeDepth compmcdShipboard Scientific Party
Sample code/labelSample labelShipboard Scientific PartyDSDP/ODP/IODP sample designation
Carbon, inorganic, totalTIC%Shipboard Scientific PartyINOR_C (wt %)
Calcium carbonateCaCO3%Shipboard Scientific PartyCaCO3 (wt %)
Carbon, totalTC%Shipboard Scientific PartyTOT_C (wt %)
Carbon, organic, totalTOC%Shipboard Scientific PartyORG_C (wt %)
Nitrogen, totalTN%Shipboard Scientific PartyN (wt %)
HydrogenHmg HC/gShipboard Scientific Party
Size:
380 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Depth comp [mcd]

Sample label

TIC [%]

CaCO3 [%]

TC [%]

TOC [%]

TN [%]

H [mg HC/g]
0.630.63171-1052A-1X-1,63-649.8882.279.910.030.19
14.4517.85171-1052A-3H-1,125-12610.1584.5310.150.000.12
17.5420.94171-1052A-3H-3,134-1398.9474.458.990.050.27
20.1223.52171-1052A-3H-5,92-939.5579.549.900.350.19
23.6325.46171-1052A-4H-1,93-949.1175.909.140.030.20
27.0428.87171-1052A-4H-3,134-1398.5971.538.680.090.26
29.4831.31171-1052A-4H-5,78-799.3677.989.460.100.000.20
32.9736.30171-1052A-5H-1,77-789.2276.839.310.090.24
36.5539.88171-1052A-5H-3,135-1408.8373.558.670.000.000.35
38.8442.17171-1052A-5H-5,64-659.3477.779.290.000.22
42.4848.40171-1052A-6H-1,78-799.4378.539.370.000.22
46.0351.95171-1052A-6H-3,133-1388.2668.788.240.000.070.32
48.4854.40171-1052A-6H-5,78-799.6580.419.700.050.000.18
51.9757.01171-1052A-7H-1,77-789.9282.649.900.000.15
55.5360.57171-1052A-7H-3,133-1389.8882.309.870.000.110.17
57.9863.02171-1052A-7H-5,78-799.9582.8410.020.070.13
61.4765.24171-1052A-8H-1,77-7810.4587.0810.420.000.11
65.0468.81171-1052A-8H-3,134-13910.1884.7810.220.040.13
67.3271.09171-1052A-8H-5,62-639.8582.019.810.000.17
70.9874.77171-1052A-9H-1,78-799.9682.999.920.000.16
74.5478.33171-1052A-9H-3,134-1399.2276.769.370.150.130.23
76.9880.77171-1052A-9H-5,78-809.6780.589.770.100.19
80.5084.52171-1052A-10H-1,80-819.4678.809.430.000.21
84.0488.06171-1052A-10H-3,134-1399.7981.529.770.000.090.17
86.4890.50171-1052A-10H-5,78-799.8782.239.880.010.180.18
89.9795.15171-1052A-11H-1,77-789.6980.719.710.020.18
93.5498.72171-1052A-11H-3,134-1399.3377.749.280.000.26
95.97101.15171-1052A-11H-5,77-789.0375.218.980.000.23
99.48105.21171-1052A-12H-1,78-799.6480.279.730.090.20
103.05108.78171-1052A-12H-3,135-1409.1776.359.180.010.000.26
105.48111.21171-1052A-12H-5,78-799.5779.749.650.080.21
108.98114.61171-1052A-13H-1,78-799.6680.469.700.040.22
112.49118.12171-1052A-13H-3,129-1349.2677.179.360.100.010.24
114.98120.61171-1052A-13H-5,78-799.6980.759.740.050.20
118.43124.45171-1052A-14H-1,73-749.8882.319.960.080.17
122.04128.06171-1052A-14H-3,134-1379.9082.469.990.090.18
124.43130.45171-1052A-14H-5,73-749.8381.929.890.060.19
127.97133.99171-1052A-15H-1,77-7810.2285.1710.270.050.14
128.55134.57171-1052A-15H-1,135-14010.7289.2810.720.000.10
130.44136.06171-1052A-16X-1,74-7510.4687.1710.390.000.010.13
134.05139.67171-1052A-16X-3,135-13910.9391.0111.000.070.08
136.70142.32171-1052A-17X-1,70-7110.6888.9510.720.040.010.11
140.32145.94171-1052A-17X-3,132-13710.9691.3011.080.120.000.09
148.12153.74171-1052A-18X-2,92-9311.0091.6510.940.000.07
150.00155.62171-1052A-18X-3,130-13510.5087.4310.710.210.09
152.52158.14171-1052A-18X-5,82-8310.6788.9210.620.000.000.09
156.12161.74171-1052A-19X-1,82-8310.3486.0910.430.090.000.13
159.60165.22171-1052A-19X-3,130-13410.0383.5310.380.350.12
162.15167.77171-1052A-19X-5,85-8611.0191.6811.120.110.010.07
163.69169.31171-1052A-19X-6,89-904.5037.494.510.010.39
168.65174.44171-1052A-21X-CC,25-272.6822.312.930.250.43
168.72174.51171-1052A-21X-CC,32-332.1818.182.390.210.40