Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Norris, Richard D; Kroon, Dick; Klaus, Adam; Shipboard Scientific Party (2005): Carbonates and bulk sediment geochemistry of ODP Hole 171-1050A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.252294

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Norris, Richard D; Kroon, Dick; Klaus, Adam; et al. (1998): Proceedings of the Ocean Drilling Program 171B Initial Reports. Proceedings of the Ocean Drilling Program, Ocean Drilling Program, 171B, online, https://doi.org/10.2973/odp.proc.ir.171b.1998
ODP/TAMU (2005): JANUS Database. Ocean Drilling Program, Texas A&M University, College Station TX 77845-9547, USA; (data copied from Janus 2005-02 to 2005-06), http://www-odp.tamu.edu/database/
Project(s):
Coverage:
Latitude: 30.099940 * Longitude: -76.235000
Date/Time Start: 1997-01-17T01:30:00 * Date/Time End: 1997-01-17T01:30:00
Minimum DEPTH, sediment/rock: 4.33 m * Maximum DEPTH, sediment/rock: 318.87 m
Event(s):
171-1050A * Latitude: 30.099940 * Longitude: -76.235000 * Date/Time: 1997-01-17T01:30:00 * Elevation: -2299.8 m * Penetration: 319.9 m * Recovery: 293.7 m * Location: Blake Nose, North Atlantic Ocean * Campaign: Leg171B * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 36 cores; 319.9 m cored; 0 m drilled; 91.8 % recovery
Comment:
Data derive from coulometer, CHNS analyzer, and pyrolysis oven (rock eval)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Depth, compositeDepth compmcdShipboard Scientific Party
Sample code/labelSample labelShipboard Scientific PartyDSDP/ODP/IODP sample designation
Carbon, inorganic, totalTIC%Shipboard Scientific PartyINOR_C (wt %)
Calcium carbonateCaCO3%Shipboard Scientific PartyCaCO3 (wt %)
Carbon, totalTC%Shipboard Scientific PartyTOT_C (wt %)
Carbon, organic, totalTOC%Shipboard Scientific PartyORG_C (wt %)
Nitrogen, totalTN%Shipboard Scientific PartyN (wt %)
HydrogenHmg HC/gShipboard Scientific Party
Size:
535 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Depth comp [mcd]

Sample label

TIC [%]

CaCO3 [%]

TC [%]

TOC [%]

TN [%]

H [mg HC/g]
4.335.17171-1050A-1X-3,133-1388.8773.918.980.110.27
5.236.07171-1050A-1X-4,73-749.1376.079.110.000.24
14.4314.62171-1050A-2H-3,133-1388.2568.718.320.070.29
16.8717.06171-1050A-2H-5,77-788.3069.168.350.050.30
23.9524.11171-1050A-3H-3,135-1408.0967.398.120.030.33
26.3826.54171-1050A-3H-5,78-798.0567.098.160.110.32
33.4533.47171-1050A-4H-3,135-1407.6063.307.750.150.34
35.8835.90171-1050A-4H-5,78-798.4670.508.500.040.30
42.9542.97171-1050A-5H-3,135-1408.5871.508.670.090.23
45.3745.39171-1050A-5H-5,77-788.2668.848.450.190.29
52.4554.34171-1050A-6H-3,135-1408.0166.728.090.080.31
54.8756.76171-1050A-6H-5,77-788.1167.538.220.110.31
61.9564.36171-1050A-7H-3,135-1408.7172.528.850.140.25
64.3866.79171-1050A-7H-5,78-798.7372.688.730.000.27
71.4674.95171-1050A-8H-3,136-1407.8165.077.830.020.000.37
73.8877.37171-1050A-8H-5,78-797.3661.307.390.030.39
76.3079.79171-1050A-8H-7,20-217.6163.427.670.060.34
80.4984.56171-1050A-9H-3,132-1377.4361.867.970.540.33
82.9587.02171-1050A-9H-5,78-797.5963.217.710.120.40
90.4495.65171-1050A-10H-3,134-1398.5571.218.620.070.29
92.9598.16171-1050A-10H-5,85-868.9774.688.910.000.26
99.92104.57171-1050A-11X-3,132-1358.4370.228.480.050.31
102.64107.29171-1050A-11X-5,104-1058.8974.058.950.060.24
105.98105.98171-1050A-12X-1,78-798.9274.308.970.050.26
106.27106.27171-1050A-12X-1,107-1098.6772.208.770.100.27
119.13123.09171-1050A-13X-3,133-1358.8673.848.870.010.25
121.61125.57171-1050A-13X-5,81-829.8682.099.320.000.23
128.73133.09171-1050A-14X-3,133-1378.4069.958.260.000.30
131.23135.59171-1050A-14X-5,83-849.3377.739.340.010.23
138.31142.67171-1050A-15X-3,131-1349.8281.829.910.090.17
140.73145.09171-1050A-15X-5,73-749.9082.439.890.000.16
147.87152.23171-1050A-16X-3,127-1319.0775.579.070.000.24
150.30154.66171-1050A-16X-5,70-719.5479.509.570.030.22
157.56161.92171-1050A-17X-3,136-1396.0850.626.040.000.54
166.52171.88171-1050A-18X-3,72-736.3152.576.250.000.48
167.11172.47171-1050A-18X-3,131-1345.6246.855.630.010.59
176.70180.12171-1050A-19X-3,130-1335.7647.955.710.000.57
179.09182.51171-1050A-19X-5,69-706.2452.016.330.090.52
183.27186.01171-1050A-20X-1,127-1287.4962.377.670.180.37
183.72186.46171-1050A-20X-2,22-236.4553.756.440.000.50
186.37189.11171-1050A-20X-3,137-1416.8456.996.770.000.46
188.92191.66171-1050A-20X-5,92-936.5354.406.590.060.49
193.95197.66171-1050A-21X-3,135-1387.4762.247.410.000.39
195.24198.95171-1050A-21X-4,114-1155.9949.865.990.000.53
196.32200.03171-1050A-21X-5,72-736.8557.086.790.000.45
202.69206.40171-1050A-22X-3,49-508.1367.738.260.130.29
203.49207.20171-1050A-22X-3,129-1327.0458.647.010.000.42
211.55214.52171-1050A-23X-2,125-1265.9849.816.180.200.010.48
213.27216.24171-1050A-23X-3,147-1507.3861.457.330.000.40
215.64218.61171-1050A-23X-5,84-856.8757.207.050.180.39
222.81226.96171-1050A-24X-3,141-1446.0950.745.990.000.50
225.09229.24171-1050A-24X-5,69-706.5254.326.500.000.48
246.16250.31171-1050A-27X-3,146-1486.8957.376.870.000.42
252.30256.45171-1050A-28X-4,50-535.9349.375.830.000.55
254.05258.20171-1050A-28X-5,75-777.3861.437.450.080.41
261.19265.34171-1050A-29X-3,129-1327.5162.567.310.000.39
264.04268.19171-1050A-29X-5,114-1158.4870.678.380.000.30
270.85275.00171-1050A-30X-3,135-1386.6055.006.550.000.49
273.27277.42171-1050A-30X-5,77-785.6046.635.430.000.58
279.31283.46171-1050A-31X-3,135-1386.6755.556.670.000.47
281.75285.90171-1050A-31X-5,79-806.0550.385.970.000.51
283.82287.97171-1050A-31X-6,136-1396.1150.916.120.010.47
286.41290.56171-1050A-32X-1,71-726.7756.436.650.000.42
288.53292.68171-1050A-32X-2,133-1368.0867.348.080.000.28
289.62293.77171-1050A-33X-1,72-735.7748.085.610.000.48
292.52296.67171-1050A-33X-3,62-638.3669.618.300.000.33
293.27297.42171-1050A-33X-3,137-1408.1968.198.120.000.27
295.68299.83171-1050A-33X-5,78-797.1759.717.140.000.40
299.09303.24171-1050A-34X-3,79-806.9758.047.210.240.41
299.54303.69171-1050A-34X-3,124-1276.3252.626.270.000.48
305.45309.60171-1050A-35X-1,55-564.1834.824.200.020.66
306.87311.02171-1050A-35X-2,47-484.6839.024.740.060.61
309.21313.36171-1050A-35X-3,131-1343.8432.003.850.010.66
311.46315.61171-1050A-35X-5,56-564.2034.974.230.030.63
312.53316.68171-1050A-35X-6,13-143.7331.053.680.000.060.65
318.87323.02171-1050A-36X-3,137-1404.4436.994.390.000.60