Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

de Graciansky, Pierre C; Poag, C Wylie (2005): Shear strength of Hole 80-549A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.230202

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
DSDP (1989): Data from the Deep Sea Drilling Project. Sediment, hard rock and reference files. National Geophysical Data Center, National Environmental Satellite, Data and Information Service, National Oceanic and Atmospheric Administration, U.S. Department of Commerce, 1, CD-ROM
Waples, Douglas W; Vaos, Staphanos P; Townsend, Hilary A; Snyder, Scott W; Sigal, Jacques; Reynolds, Leslie A; Otsuka, Kenichi; Müller, Carla; Montadert, Lucien; Mazzullo, James M; Masson, Douglas G; Cunningham, Robert; Loubere, Paul; de Graciansky, Pierre C; Poag, C Wylie (1985): Initial Reports of the Deep Sea Drilling Project. Initial Reports of the Deep Sea Drilling Project, U.S. Government Printing Office, LXXX, 679 pp + 1258 pp, https://doi.org/10.2973/dsdp.proc.80.1985
Project(s):
Coverage:
Latitude: 49.088200 * Longitude: -13.098200
Date/Time Start: 1981-06-15T00:00:00 * Date/Time End: 1981-06-15T00:00:00
Minimum DEPTH, sediment/rock: 9.25 m * Maximum DEPTH, sediment/rock: 156.90 m
Event(s):
80-549A * Latitude: 49.088200 * Longitude: -13.098200 * Date/Time: 1981-06-15T00:00:00 * Elevation: -2513.0 m * Penetration: 200.5 m * Recovery: 143.6 m * Location: North Atlantic/SPUR * Campaign: Leg80 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 39 cores; 197 m cored; 3.5 m drilled; 72.9 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Sample code/labelSample labelDSDPDSDP/ODP/IODP sample designation
Shear strength, primaryShear strkPaDSDP
CommentCommentDSDPData type/Torvane capacity
Size:
156 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Sample label

Shear str [kPa]

Comment
9.2580-549A-2-1,12514.65Torvane/Low
10.7080-549A-2-2,12010.74Torvane/Low
12.2080-549A-2-3,12015.04Torvane/Low
13.7080-549A-2-4,12016.60Torvane/Middle
15.2080-549A-2-5,12016.60Torvane/Middle
37.9080-549A-5-1,14028.32Torvane/Middle
39.4080-549A-5-2,14031.25Torvane/Middle
40.9080-549A-5-3,14034.18Torvane/Middle
42.4080-549A-5-4,14037.11Torvane/Middle
43.7080-549A-5-5,12033.20Torvane/Middle
47.4080-549A-6-1,14031.25Torvane/Middle
48.9080-549A-6-2,14037.11Torvane/Middle
50.4080-549A-6-3,14023.44Torvane/Middle
51.9080-549A-6-4,14016.60Torvane/Middle
53.4080-549A-6-5,14021.48Torvane/Middle
56.9080-549A-7-1,14031.25Torvane/Middle
58.4080-549A-7-2,14036.13Torvane/Middle
59.9080-549A-7-3,14033.20Torvane/Middle
61.4080-549A-7-4,14037.11Torvane/Middle
62.9080-549A-7-5,14036.13Torvane/Middle
64.4080-549A-7-6,14026.37Torvane/Middle
66.4080-549A-8-1,14039.06Torvane/Middle
67.9080-549A-8-2,14033.20Torvane/Middle
69.4080-549A-8-3,14035.15Torvane/Middle
70.9080-549A-8-4,14035.15Torvane/Middle
72.4580-549A-8-5,14541.01Torvane/Middle
73.1080-549A-8-6,6041.99Torvane/Middle
75.6480-549A-9-1,11445.89Torvane/Middle
77.4080-549A-9-2,14052.73Torvane/Middle
78.9080-549A-9-3,14079.10Torvane/Middle
80.4080-549A-9-4,14065.42Torvane/Middle
81.8080-549A-9-5,13058.59Torvane/Middle
85.4080-549A-10-1,14034.18Torvane/High
86.9080-549A-10-2,14034.18Torvane/High
88.4080-549A-10-3,14043.94Torvane/High
89.9080-549A-10-4,14039.06Torvane/High
91.4080-549A-10-5,14043.94Torvane/High
92.9080-549A-10-6,14061.03Torvane/High
94.9080-549A-11-1,14041.50Torvane/High
96.4080-549A-11-2,14056.15Torvane/High
97.9080-549A-11-3,14046.38Torvane/High
99.4080-549A-11-4,14051.27Torvane/High
100.9080-549A-11-5,14080.56Torvane/High
102.4080-549A-11-6,14053.71Torvane/High
112.4080-549A-14-1,14048.82Torvane/High
112.5580-549A-14-2,553.71Torvane/High
139.2780-549A-27-1,7746.38Torvane/High
139.5580-549A-27-1,10539.06Torvane/High
141.4080-549A-28-1,14051.27Torvane/High
151.9080-549A-33-1,14078.12Torvane/High
153.4080-549A-33-2,14095.21Torvane/High
156.9080-549A-34-1,140102.53Torvane/High