Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Burkill, Peter (2004): Physical oceanography at bottle station GOM4/3 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.135645

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
BODC (1998): Arabesque data from Discovery cruises 210 (27 Aug - 4 Oct 1994) and 212 (16 Nov - 19 Dec 1994). British Oceanographic Data Center, Birkenhead, CD-ROM, https://www.bodc.ac.uk/resources/products/data/bodc_products/arabesque/
Further details:
ARABESQUE - Water Sample data documentation. BottleData.pdf
Project(s):
Coverage:
Latitude: 23.914700 * Longitude: 59.251000
Date/Time Start: 1994-11-19T05:40:00 * Date/Time End: 1994-11-19T06:08:00
Minimum DEPTH, water: 0.5 m * Maximum DEPTH, water: 75.0 m
Event(s):
GOM4/3 (74792) * Latitude: 23.914700 * Longitude: 59.251000 * Date/Time Start: 1994-11-19T05:40:00 * Date/Time End: 1994-11-19T06:08:00 * Elevation: -3319.4 m * Campaign: D212 * Basis: Discovery (1962) * Method/Device: CTD/Rosette (CTD-RO)
Comment:
Plymouth Marine Laboratory. Authorship was originally "BODC" and was changed by request of the BODC.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, waterDepth watermGeocode
Optical beam attenuation coefficient, 660 nmbac6601/mBODCTransmissometer
Chlorophyll totalChl totµg/lBODCFluorometer, in-situ
OxygenO2µmol/lBODCOxygen probe, Beckmann Instruments
Irradiance, downward PAREdµmol/m2/sBODCLight meter, hemispherical photodiode
Irradiance, upward PAREuµmol/m2/sBODCLight meter, hemispherical photodiode
Oxygen saturationO2 sat%BODCOxygen, Benson & Krause 1984
SalinitySalBODCCTD
Density, sigma-theta (0)Sigma-thetakg/m3BODCCalculated
10 Temperature, waterTemp°CBODCCTD
Size:
75 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth water [m]

bac660 [1/m]

Chl tot [µg/l]

O2 [µmol/l]

Ed [µmol/m2/s]

Eu [µmol/m2/s]

O2 sat [%]

Sal

Sigma-theta [kg/m3]
10 
Temp [°C]
0.50.571100.20595196.3698.3767237.0085523.9618527.83700
0.70.549600.29315202.200.7198637.26430101.6247936.7536023.6772028.11900
7.80.548100.32530199.250.3889414.44680100.1448436.7526023.6763028.12100
10.50.572200.22596188.1894.2668537.0005523.9583827.83150
28.20.455150.37774100.701.1246946.3380436.4013524.9606923.13520
30.10.562900.23933184.8092.5500837.0040523.9675827.81600
42.20.591400.2757044.6420.8658836.4645524.7924823.87400
48.30.413000.2780365.4029.8275836.4429425.1847522.47267
50.10.595870.383976.572.9979736.3518825.1090822.49567
75.00.524930.268892.911.2749036.1752225.5711020.34667