Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Franke, Christine; Hofmann, Daniela; von Dobeneck, Tilo (2004): Sedimentologic and magnetic data of sediment core GeoB6425-2, complete sample set [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.132695, In supplement to: Franke, C et al. (2004): Does lithology influence relative paleointensity records? A statistical analysis on South Atlantic pelagic sediments. Physics of the Earth and Planetary Interior, 147, 285-296, https://doi.org/10.1016/j.pepi.2004.07.004

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -33.825200 * Longitude: -23.587300
Date/Time Start: 2000-03-02T08:02:00 * Date/Time End: 2000-03-02T08:02:00
Minimum DEPTH, sediment/rock: 0.05 m * Maximum DEPTH, sediment/rock: 7.15 m
Event(s):
GeoB6425-2 * Latitude: -33.825200 * Longitude: -23.587300 * Date/Time: 2000-03-02T08:02:00 * Elevation: -4352.0 m * Recovery: 10.89 m * Location: Central South Atlantic * Campaign: M46/4 * Basis: Meteor (1986) * Method/Device: Gravity corer (Kiel type) (SL) * Comment: geology and geophysics, CTD at 50 m
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
NRM, median destructive field of natural remanent magnetization, alternating fieldMDF (NRM)mTFranke, ChristineMagnetometer, cryogenic, pass-through, 2G Enterprises 755 R
ARM, median destructive field of anhysteretic remanent magnetizationMDF (ARM)mTFranke, ChristineMagnetometer, cryogenic, pass-through, 2G Enterprises 755 R
Magnetic susceptibility, volumekappa10-6 SIFranke, ChristineBartington MS2F spot sensor
NRM, Median destructive field/ARM, Median destructive field ratioMDF (NRM)/MDF (ARM)Franke, ChristineCalculated, see reference(s)
IronFecpsFranke, ChristineX-ray fluorescence core scanner (XRF)
Iron/susceptibility, volume ratioFe/kcps/106 SIFranke, ChristineCalculated, see reference(s)
Opal, biogenic silicabSiO2%Franke, ChristineOpal, auto analysis (Müller & Schneider, 1993)
Calcium carbonateCaCO3%Franke, ChristineElement analyser CHN-O Rapid, Heraeus
10 SmectiteSme%Franke, ChristineX-ray diffraction TEXTUR, clay fraction
11 IlliteIll%Franke, ChristineX-ray diffraction TEXTUR, clay fraction
12 KaoliniteKln%Franke, ChristineX-ray diffraction TEXTUR, clay fraction
13 ChloriteChl%Franke, ChristineX-ray diffraction TEXTUR, clay fraction
14 Size fraction < 0.002 mm, clay<2 µm%Franke, ChristineGrain size, LASER Particle Sizer
15 SiltSilt%Franke, ChristineGrain size, LASER Particle Sizer
16 SandSand%Franke, ChristineGrain size, LASER Particle Sizer
17 Synthetic record 800Sint-800Franke, ChristineCalculated, see reference(s)
18 (NRM/ARM)/Sint-800 ratio(NRM/ARM)/Sint-800Franke, ChristineCalculated, see reference(s)
Size:
285 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

MDF (NRM) [mT]

MDF (ARM) [mT]

kappa [10-6 SI]

MDF (NRM)/MDF (ARM)

Fe [cps]

Fe/k [cps/106 SI]

bSiO2 [%]

CaCO3 [%]
10 
Sme [%]
11 
Ill [%]
12 
Kln [%]
13 
Chl [%]
14 
<2 µm [%]
15 
Silt [%]
16 
Sand [%]
17 
Sint-800
18 
(NRM/ARM)/Sint-800
0.0515.8084.40210.00.18721115.05.31.8574.7420.5669.819.631.17400.1595
0.2529.00115.00363.80.25222292.76.31.8659.6628.0244.969.4320.6022.4271.715.870.87870.2870
0.5115.4087.60231.70.17561497.36.51.8570.0235.6938.649.5218.4625.2268.686.100.94020.1868
0.7525.80144.00403.60.17923706.29.21.8545.1426.3349.337.9618.5722.0374.563.410.92250.1942
1.0014.60121.00295.00.12071885.56.41.9762.4637.8036.327.7418.9722.6170.387.010.67110.1798
1.2516.3086.20211.80.18911376.96.51.8572.5842.8733.6815.978.2623.0770.936.000.79040.2392
1.5046.20120.00338.50.38502158.46.41.8562.7837.5734.9716.3711.3523.7667.159.090.92960.4141
1.7025.50116.00334.90.21982360.87.01.6059.5439.2034.4211.5317.4222.9169.108.001.01030.2176
1.9512.80177.00476.00.07235322.511.21.8526.5833.8345.658.3114.3418.0581.470.480.51720.1398
2.2014.20121.00273.30.11742294.88.41.8557.9639.1135.7711.7814.8719.7772.098.130.87820.1336
2.3514.30138.00318.60.10362566.08.11.8355.4436.2935.5516.7512.1325.0374.870.101.20430.0860
2.5522.30111.00275.10.20091971.97.21.8564.6034.5444.058.1815.5825.6570.743.600.96620.2079
2.8039.90214.00566.50.18645528.99.81.8529.6229.9547.908.5116.6818.6479.192.170.78270.2382
6.2013.80219.00486.90.06305315.610.92.3525.4642.9538.158.7713.8118.9279.941.140.79770.0790
6.6025.00121.00322.20.20662183.16.82.1466.1047.7231.507.1513.2827.4168.464.120.92590.2231
6.9050.80145.00381.90.35032374.06.21.4158.0651.7623.4511.5411.3026.6569.364.001.23900.2828
7.1547.20241.00649.80.19595457.78.41.6517.7238.4339.988.6619.0716.9082.430.660.77440.2529