Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT011_7-TM58 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123651
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: 1.176700 * Longitude: -140.015000
Date/Time Start: 1992-08-27T13:04:00 * Date/Time End: 1992-08-27T13:04:00
Minimum DEPTH, water: 0 m * Maximum DEPTH, water: 150 m
Event(s):
TT011_7-TM58 (08271304 TM_058) * Latitude: 1.176700 * Longitude: -140.015000 * Date/Time: 1992-08-27T13:04:00 * Location: Equatorial Pacific * Campaign: TT011 * Basis: Thomas G. Thompson * Method/Device: Bottle, multi level trace metal (MLTM)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
72 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa |
---|---|---|---|---|---|---|---|---|---|
0 | 0.540 | 10.00 | 8.29 | 0.01 | 1.96 | 1.02 | 0.230 | 0.042 | 1.93 |
15 | 0.540 | 10.00 | 8.29 | 0.01 | 2.67 | 1.43 | 0.303 | 0.079 | 1.87 |
30 | 0.540 | 10.00 | 8.29 | 0.01 | 3.96 | 2.15 | 0.443 | 0.133 | 1.85 |
45 | 0.540 | 10.00 | 8.29 | 0.01 | 4.85 | 2.74 | 0.516 | 0.218 | 1.77 |
60 | 0.540 | 10.00 | 8.29 | 0.01 | 5.18 | 2.93 | 0.550 | 0.235 | 1.77 |
75 | 0.540 | 10.00 | 8.29 | 0.01 | 5.76 | 3.35 | 0.589 | 0.309 | 1.72 |
100 | 0.540 | 10.00 | 8.29 | 0.01 | 4.53 | 2.66 | 0.457 | 0.256 | 1.71 |
150 | 0.540 | 31.60 | 27.68 | 0.04 | 2.09 | 1.44 | 0.048 | 0.065 | 1.46 |