Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT011_4-TM36 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123627
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: 5.008300 * Longitude: -139.820000
Date/Time Start: 1992-08-20T01:10:00 * Date/Time End: 1992-08-20T01:10:00
Minimum DEPTH, water: 1 m * Maximum DEPTH, water: 118 m
Event(s):
TT011_4-TM36 (08200110 TM_036) * Latitude: 5.008300 * Longitude: -139.820000 * Date/Time: 1992-08-20T01:10:00 * Location: Equatorial Pacific * Campaign: TT011 * Basis: Thomas G. Thompson * Method/Device: Bottle, multi level trace metal (MLTM)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
72 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa |
---|---|---|---|---|---|---|---|---|---|
1 | 0.540 | 31.60 | 27.68 | 0.04 | 5.42 | 2.93 | 0.182 | 0.050 | 1.86 |
12 | 0.540 | 31.60 | 27.68 | 0.04 | 5.26 | 2.85 | 0.176 | 0.050 | 1.86 |
21 | 0.540 | 31.60 | 27.68 | 0.04 | 5.34 | 2.87 | 0.181 | 0.047 | 1.87 |
34 | 0.540 | 31.60 | 27.68 | 0.04 | 5.67 | 3.05 | 0.192 | 0.051 | 1.87 |
45 | 0.540 | 31.60 | 27.68 | 0.04 | 5.56 | 3.03 | 0.185 | 0.056 | 1.85 |
60 | 0.540 | 10.00 | 8.29 | 0.01 | 2.08 | 1.15 | 0.227 | 0.079 | 1.82 |
79 | 0.540 | 10.00 | 8.29 | 0.01 | 2.16 | 1.21 | 0.232 | 0.090 | 1.79 |
118 | 0.540 | 31.60 | 27.68 | 0.04 | 4.40 | 2.74 | 0.122 | 0.096 | 1.61 |