Coverage:
Latitude: 4.943300 * Longitude: -139.796700
Date/Time Start: 1992-08-20T07:54:00 * Date/Time End: 1992-08-20T07:54:00
Minimum DEPTH, water: 0 m * Maximum DEPTH, water: 250 m
Event(s):
TT011_4-CTD50 (08200754 CTD-050) * Latitude: 4.943300 * Longitude: -139.796700 * Date/Time: 1992-08-20T07:54:00 * Campaign: TT011 * Basis: Thomas G. Thompson * Method/Device: CTD/Rosette (CTD-RO)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan | |||
11 | Bottle number | Bottle | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
120 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa | 11 Bottle |
---|---|---|---|---|---|---|---|---|---|---|
0 | 0.540 | 10.00 | 8.29 | 0.01 | 1.89 | 1.02 | 0.213 | 0.059 | 1.86 | 24 |
20 | 0.540 | 31.60 | 27.68 | 0.04 | 6.22 | 3.36 | 0.209 | 0.058 | 1.86 | 22 |
40 | 0.540 | 10.00 | 8.29 | 0.01 | 2.03 | 1.11 | 0.225 | 0.071 | 1.84 | 20 |
50 | 0.540 | 10.00 | 8.29 | 0.01 | 1.96 | 1.08 | 0.215 | 0.073 | 1.82 | 19 |
60 | 0.540 | 10.00 | 8.29 | 0.01 | 1.99 | 1.10 | 0.218 | 0.076 | 1.82 | 18 |
70 | 0.540 | 10.00 | 8.29 | 0.01 | 2.45 | 1.38 | 0.262 | 0.107 | 1.78 | 17 |
80 | 0.540 | 10.00 | 8.29 | 0.01 | 2.65 | 1.54 | 0.271 | 0.140 | 1.73 | 16 |
100 | 0.540 | 31.60 | 27.68 | 0.04 | 5.55 | 3.31 | 0.164 | 0.099 | 1.69 | 14 |
120 | 0.540 | 31.60 | 27.68 | 0.04 | 5.08 | 3.12 | 0.143 | 0.105 | 1.64 | 12 |
150 | 0.540 | 31.60 | 27.68 | 0.04 | 2.48 | 1.66 | 0.060 | 0.070 | 1.51 | 9 |
200 | 0.540 | 316.00 | 278.43 | 0.43 | 3.96 | 3.36 | 0.004 | 0.019 | 1.20 | 7 |
250 | 0.540 | 316.00 | 278.43 | 0.43 | 3.12 | 3.06 | 0.000 | 0.021 | 1.02 | 5 |