Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT011_2-TM19 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123612
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: 9.150000 * Longitude: -139.846700
Date/Time Start: 1992-08-15T01:00:00 * Date/Time End: 1992-08-15T01:00:00
Minimum DEPTH, water: 1 m * Maximum DEPTH, water: 118 m
Event(s):
TT011_2-TM19 (08150100 TM_019) * Latitude: 9.150000 * Longitude: -139.846700 * Date/Time: 1992-08-15T01:00:00 * Location: Equatorial Pacific * Campaign: TT011 * Basis: Thomas G. Thompson * Method/Device: Bottle, multi level trace metal (MLTM)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
72 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa |
---|---|---|---|---|---|---|---|---|---|
1 | 0.540 | 31.60 | 27.68 | 0.04 | 2.09 | 1.10 | 0.072 | 0.013 | 1.93 |
12 | 0.540 | 31.60 | 27.68 | 0.04 | 2.04 | 1.07 | 0.071 | 0.012 | 1.94 |
21 | 0.540 | 31.60 | 27.68 | 0.04 | 2.07 | 1.10 | 0.071 | 0.014 | 1.92 |
34 | 0.540 | 31.60 | 27.68 | 0.04 | 2.38 | 1.28 | 0.081 | 0.019 | 1.89 |
45 | 0.540 | 31.60 | 27.68 | 0.04 | 3.56 | 1.94 | 0.119 | 0.034 | 1.85 |
60 | 0.540 | 10.00 | 8.29 | 0.01 | 2.23 | 1.26 | 0.237 | 0.099 | 1.78 |
79 | 0.540 | 10.00 | 8.29 | 0.01 | 3.27 | 1.94 | 0.325 | 0.194 | 1.69 |
118 | 0.540 | 31.60 | 27.68 | 0.04 | 5.74 | 3.63 | 0.154 | 0.135 | 1.59 |