Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT011_13-TM105 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123589
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: -7.006700 * Longitude: -138.486700
Date/Time Start: 1992-09-11T03:55:00 * Date/Time End: 1992-09-11T03:55:00
Minimum DEPTH, water: 1 m * Maximum DEPTH, water: 118 m
Event(s):
TT011_13-TM105 (09110355 TM_105) * Latitude: -7.006700 * Longitude: -138.486700 * Date/Time: 1992-09-11T03:55:00 * Location: Equatorial Pacific * Campaign: TT011 * Basis: Thomas G. Thompson * Method/Device: Bottle, multi level trace metal (MLTM)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
72 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa |
---|---|---|---|---|---|---|---|---|---|
1 | 0.540 | 31.60 | 27.68 | 0.04 | 4.66 | 2.60 | 0.151 | 0.055 | 1.80 |
12 | 0.540 | 31.60 | 27.68 | 0.04 | 4.76 | 2.65 | 0.154 | 0.056 | 1.81 |
21 | 0.540 | 31.60 | 27.68 | 0.04 | 4.83 | 2.70 | 0.156 | 0.058 | 1.80 |
34 | 0.540 | 31.60 | 27.68 | 0.04 | 5.22 | 2.92 | 0.168 | 0.064 | 1.80 |
45 | 0.540 | 31.60 | 27.68 | 0.04 | 5.70 | 3.21 | 0.182 | 0.073 | 1.79 |
60 | 0.540 | 31.60 | 27.68 | 0.04 | 6.16 | 3.50 | 0.195 | 0.084 | 1.77 |
79 | 0.540 | 10.00 | 8.29 | 0.01 | 1.97 | 1.14 | 0.203 | 0.101 | 1.73 |
118 | 0.540 | 31.60 | 27.68 | 0.04 | 5.98 | 3.83 | 0.157 | 0.148 | 1.57 |