Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT007_8-TM2 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123549
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: 0.000000 * Longitude: -140.038300
Date/Time Start: 1992-02-23T01:40:00 * Date/Time End: 1992-02-23T01:40:00
Minimum DEPTH, water: 3 m * Maximum DEPTH, water: 106 m
Event(s):
TT007_8-TM2 (02230140 TM-2) * Latitude: 0.000000 * Longitude: -140.038300 * Date/Time: 1992-02-23T01:40:00 * Location: Equatorial Pacific * Campaign: TT007 * Basis: Thomas G. Thompson * Method/Device: Bottle, multi level trace metal (MLTM)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
72 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa |
---|---|---|---|---|---|---|---|---|---|
3 | 0.540 | 10.00 | 8.29 | 0.01 | 2.07 | 1.14 | 0.227 | 0.077 | 1.82 |
11 | 0.540 | 10.00 | 8.29 | 0.01 | 2.12 | 1.17 | 0.232 | 0.080 | 1.82 |
19 | 0.540 | 10.00 | 8.29 | 0.01 | 2.40 | 1.34 | 0.259 | 0.099 | 1.80 |
30 | 0.540 | 10.00 | 8.29 | 0.01 | 2.62 | 1.47 | 0.281 | 0.112 | 1.79 |
39 | 0.540 | 10.00 | 8.29 | 0.01 | 2.60 | 1.46 | 0.279 | 0.111 | 1.79 |
46 | 0.540 | 10.00 | 8.29 | 0.01 | 2.61 | 1.48 | 0.276 | 0.119 | 1.77 |
71 | 0.540 | 10.00 | 8.29 | 0.01 | 2.75 | 1.61 | 0.279 | 0.152 | 1.71 |
106 | 0.540 | 10.00 | 8.29 | 0.01 | 1.90 | 1.10 | 0.196 | 0.098 | 1.73 |