Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT007_8-CTD97 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123548
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: 0.001800 * Longitude: -140.329600
Date/Time Start: 1992-02-24T12:30:00 * Date/Time End: 1992-02-24T12:30:00
Minimum DEPTH, water: 0 m * Maximum DEPTH, water: 250 m
Event(s):
TT007_8-CTD97 (02241230 CTD-97) * Latitude: 0.001800 * Longitude: -140.329600 * Date/Time: 1992-02-24T12:30:00 * Campaign: TT007 * Basis: Thomas G. Thompson * Method/Device: CTD/Rosette (CTD-RO)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan | |||
11 | Bottle number | Bottle | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
120 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa | 11 Bottle |
---|---|---|---|---|---|---|---|---|---|---|
0 | 0.540 | 31.60 | 27.68 | 0.04 | 5.33 | 2.84 | 0.182 | 0.043 | 1.89 | 24 |
20 | 0.540 | 10.00 | 8.29 | 0.01 | 2.66 | 1.48 | 0.289 | 0.107 | 1.80 | 22 |
40 | 0.540 | 10.00 | 8.29 | 0.01 | 2.85 | 1.64 | 0.296 | 0.143 | 1.74 | 20 |
50 | 0.540 | 10.00 | 8.29 | 0.01 | 2.81 | 1.66 | 0.281 | 0.163 | 1.70 | 19 |
60 | 0.540 | 10.00 | 8.29 | 0.01 | 2.75 | 1.64 | 0.271 | 0.167 | 1.68 | 18 |
70 | 0.540 | 10.00 | 8.29 | 0.01 | 2.12 | 1.23 | 0.218 | 0.111 | 1.73 | 17 |
80 | 0.540 | 31.60 | 27.68 | 0.04 | 5.67 | 3.30 | 0.174 | 0.089 | 1.73 | 16 |
100 | 0.540 | 31.60 | 27.68 | 0.04 | 2.93 | 1.82 | 0.081 | 0.062 | 1.62 | 14 |
120 | 0.540 | 100.00 | 95.48 | 0.15 | 4.41 | 2.66 | 0.037 | 0.021 | 1.70 | 12 |
150 | 0.540 | 316.00 | 278.43 | 0.43 | 2.77 | 2.26 | 0.004 | 0.011 | 1.28 | 9 |
200 | 0.540 | 316.00 | 278.43 | 0.43 | 2.46 | 2.15 | 0.002 | 0.012 | 1.18 | 7 |
250 | 0.540 | 316.00 | 278.43 | 0.43 | 2.64 | 2.57 | 0.001 | 0.017 | 1.03 | 5 |