Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT007_15-TM6 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123503
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: -12.111300 * Longitude: -135.048700
Date/Time Start: 1992-03-09T10:30:00 * Date/Time End: 1992-03-09T10:30:00
Minimum DEPTH, water: 20 m * Maximum DEPTH, water: 105 m
Event(s):
TT007_15-TM6 (03091030 TM-6) * Latitude: -12.111300 * Longitude: -135.048700 * Date/Time: 1992-03-09T10:30:00 * Location: Equatorial Pacific * Campaign: TT007 * Basis: Thomas G. Thompson * Method/Device: Bottle, multi level trace metal (MLTM)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Fo/Fa ratio | Fo/Fa | Newton, Jan | |||
9 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
10 | Phaeopigments | Phae | µg/l | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
72 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Fo/Fa | 9 Chl a [µg/l] (Fluorometry) | 10 Phae [µg/l] |
---|---|---|---|---|---|---|---|---|---|
20 | 0.540 | 31.60 | 27.68 | 0.04 | 3.58 | 1.93 | 1.87 | 0.121 | 0.031 |
20 | 0.540 | 31.60 | 27.68 | 0.04 | 3.53 | 1.90 | 1.88 | 0.119 | 0.030 |
20 | 0.540 | 31.60 | 27.68 | 0.04 | 3.49 | 1.89 | 1.86 | 0.117 | 0.032 |
40 | 0.540 | 31.60 | 27.68 | 0.04 | 4.37 | 2.36 | 1.87 | 0.147 | 0.040 |
55 | 0.540 | 31.60 | 27.68 | 0.04 | 5.73 | 3.12 | 1.85 | 0.191 | 0.057 |
65 | 0.540 | 31.60 | 27.68 | 0.04 | 5.99 | 3.29 | 1.83 | 0.198 | 0.064 |
105 | 0.540 | 10.00 | 8.29 | 0.01 | 2.79 | 1.70 | 1.64 | 0.267 | 0.188 |
105 | 0.540 | 10.00 | 8.29 | 0.01 | 2.69 | 1.72 | 1.57 | 0.237 | 0.223 |