Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment at station TT007_12-TM1 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.123492
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Newton, Jan; Murray, James W (2003): Fluorometric chlorophyll a and total phaeopigment. United States JGOFS Process Study Data 1989-1998; CD-ROM volume 1, version 2, Woods Hole Oceanographic Institution, USA: U.S. JGOFS Data Management Office
Further details:
Niskin bottle data quality review notes. US JGOFS (Joint Global Ocean Flux Study) Data System, bottleQC.htm
Project(s):
Joint Global Ocean Flux Study (JGOFS)
Coverage:
Latitude: -5.073700 * Longitude: -140.042800
Date/Time Start: 1992-03-04T01:35:00 * Date/Time End: 1992-03-04T01:35:00
Minimum DEPTH, water: 5 m * Maximum DEPTH, water: 130 m
Event(s):
TT007_12-TM1 (03040135 TM-1) * Latitude: -5.073700 * Longitude: -140.042800 * Date/Time: 1992-03-04T01:35:00 * Location: Equatorial Pacific * Campaign: TT007 * Basis: Thomas G. Thompson * Method/Device: Bottle, multi level trace metal (MLTM)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, water | Depth water | m | Geocode | ||
2 | Sample volume | Samp vol | l | Newton, Jan | volume of sample filtered | |
3 | Fluorometer, sensitivity scale | sensitivity scale | Newton, Jan | |||
4 | Fluorometer, door factor | df | Newton, Jan | |||
5 | Fluorometer, calibration factor | B | Newton, Jan | |||
6 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorometer, in-situ | |
7 | Fluorescence | Fluorescence | arbitrary units | Newton, Jan | Fluorescence determination after 2 drops 1N HCL | |
8 | Chlorophyll a | Chl a | µg/l | Newton, Jan | Fluorometry | |
9 | Phaeopigments | Phae | µg/l | Newton, Jan | ||
10 | Fo/Fa ratio | Fo/Fa | Newton, Jan |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
72 data points
Data
1 Depth water [m] | 2 Samp vol [l] (volume of sample filtered) | 3 sensitivity scale | 4 df | 5 B | 6 Fluorescence [arbitrary units] (Fluorometer, in-situ) | 7 Fluorescence [arbitrary units] (Fluorescence determination af...) | 8 Chl a [µg/l] (Fluorometry) | 9 Phae [µg/l] | 10 Fo/Fa |
---|---|---|---|---|---|---|---|---|---|
5 | 0.540 | 31.60 | 27.68 | 0.04 | 5.24 | 2.92 | 0.170 | 0.062 | 1.81 |
5 | 0.540 | 31.60 | 27.68 | 0.04 | 5.23 | 2.92 | 0.169 | 0.063 | 1.80 |
19 | 0.540 | 31.60 | 27.68 | 0.04 | 6.24 | 3.41 | 0.207 | 0.064 | 1.84 |
40 | 0.540 | 31.60 | 27.68 | 0.04 | 5.28 | 2.97 | 0.169 | 0.067 | 1.79 |
54 | 0.540 | 31.60 | 27.68 | 0.04 | 5.16 | 2.88 | 0.167 | 0.062 | 1.80 |
66 | 0.540 | 31.60 | 27.68 | 0.04 | 5.58 | 3.12 | 0.180 | 0.068 | 1.80 |
106 | 0.540 | 31.60 | 27.68 | 0.04 | 7.46 | 4.40 | 0.224 | 0.127 | 1.70 |
130 | 0.540 | 31.60 | 27.68 | 0.04 | 7.07 | 4.42 | 0.194 | 0.159 | 1.61 |