Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Nizou, Jean; Demory, François (2015): Low-field magnetic susceptibility and magnetic parameters of the navigation channel dried grab samples [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.830269, In supplement to: Nizou, Jean; Demory, François; Dubrulle-Brunaud, Carole (2016): Monitoring of dredged-dumped sediment dispersal off the Bay of the Seine (northern France) using environmental magnetism. Comptes Rendus Geoscience, 348(6), 451-461, https://doi.org/10.1016/j.crte.2015.02.005

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Median Latitude: 49.435493 * Median Longitude: 0.184483 * South-bound Latitude: 49.431538 * West-bound Longitude: 0.073266 * North-bound Latitude: 49.439447 * East-bound Longitude: 0.295701
Event(s):
Bay_of_Seine_Brèche (Brèche) * Latitude: 49.431538 * Longitude: 0.295701 * Location: Bay of Seine * Comment: Navigation channel
Bay_of_Seine_Engainement (Engainement) * Latitude: 49.439447 * Longitude: 0.073266 * Location: Bay of Seine * Comment: Navigation channel
Comment:
Low-field magnetic susceptibility of every sample was measured with an MFK1 susceptibilimeter (AGICO; K_LF ). The obtained value was normalized by the weight of the sample to determine the specific low-field magnetic susceptibility, X_LF . Determination of Anhysteretic Remanent Magnetization (ARM), Saturation Isothermal Remanent Magnetization (SIRM) and Isothermal Remanent Magnetization (IRM) was performed with a superconducting rock magnetometer SRM760R (2G enterprises). The ARM is an artificial magnetization gained in an alternating magnetic field of 100 mT superimposed on a steady field of 50 µT, which is comparable to the strength of the geomagnetic field. The ARM is afterward subject to demagnetization at 30 mT (ARM_30 ). The SIRM was acquired at 3 T and the IRM at 0.3 T in the opposite direction using a pulse magnetizer MMPM9 (Magnetic Measurements ltd). The S-ratio was calculated after the formula 0.5(1-IRM/SIRM) and allows for an estimation of the relative abundance of high coercivity minerals. TheS-ratio comesclose to 1when low-coercive mineralssuch a as magnetite dominate the signal, and decreaseswith increasing amount of high-coercive mineralssuch as hematite (Bloemendal et al., 1992).The Hard Isothermal Remanent Magnetization (HIRM) was calculated after the formula (SIRM-IRM)/2 and allows for an estimation of the absolute concentration of high coercivity minerals (e.g. hematite).ARM/SIRM is used as an estimator of the relative magnetic grain size. ARM_30 /ARM is also used as a magnetic grain-size estimator since samples display a constant mineralogy.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEvent
2Sample code/labelSample labelNizou, Jean
3Dry massDry mgNizou, Jean
4Magnetic susceptibility, volumekappa10-6 SINizou, JeanSusceptibilimeter, MFK1 (AGICO; K_LF)Low-field
5Susceptibility, specific, low-field mass-normalizedchi_lf10-9 m3/kgNizou, JeanSusceptibilimeter, MFK1 (AGICO; K_LF)
6Anhysteretic Remanent MagnetizationARM10-3 Am2Nizou, JeanSuperconducting rock magnetometer SRM760R (2G enterprises)
7Anhysteretic Remanent MagnetizationARM10-3 Am2Nizou, JeanSuperconducting rock magnetometer SRM760R (2G enterprises)ARM30
8Saturation isothermal remanent magnetizationSIRM10-3 A m2Nizou, JeanMagnetometer SRM760R (2G enterprises); pulse magnetizer MMPM93T
9Isothermal Remanent MagnetizationIRM10-3 Am2Nizou, JeanMagnetometer SRM760R (2G enterprises); pulse magnetizer MMPM9-0.3T
10Anhysteretic remanent magnetization, Intensity, per unit massInten ARM10-6 A*m2/kgNizou, Jean
11Anhysteretic remanent magnetization, Intensity, per unit massInten ARM10-6 A*m2/kgNizou, JeanARM30
12Saturation isothermal remanent magnetizationSIRM10-6 A m2/kgNizou, JeanSIRM 3T
13Isothermal remanent magnetization, Intensity, per unit massInten IRM10-6 A*m2/kgNizou, JeanIRM-0.3T
14S-ratio (hematite/magnetite)S-rNizou, Jean
15Hard isothermal remanent magnetization, Intensity, per unit massInten HIRM10-6 A*m2/kgNizou, Jean
16ARM/ARMARM/ARMNizou, JeanARM30/ARM
17Anhysteretic remanent magnetization/saturation isothermal remanent magnetization ratioARM/SIRMNizou, Jean
Size:
160 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML