# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
1 | LATITUDE | Latitude | | | | Geocode |
2 | LONGITUDE | Longitude | | | | Geocode |
3 | DEPTH, sediment/rock | Depth sed | m | | | Geocode |
4 | Sample code/label | Sample label | | Reimann, Clemens | | |
5 | Description | Description | | Reimann, Clemens | | |
6 | Mercury | Hg | mg/kg | Reimann, Clemens | CV-AAS, conc. HNO3 (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.06 ppm |
7 | Mercury | Hg | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
8 | Aluminium | Al | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
9 | Aluminium | Al | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 300 ppm |
10 | Boron | B | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
11 | Barium | Ba | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
12 | Barium | Ba | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 50 ppm |
13 | Beryllium | Be | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.05 ppm |
14 | Calcium | Ca | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
15 | Calcium | Ca | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 50 ppm |
16 | Calcium | Ca | % | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 % |
17 | Cobalt | Co | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.2 ppm |
18 | Cobalt | Co | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
19 | Chromium | Cr | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
20 | Chromium | Cr | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 5 ppm |
21 | Copper | Cu | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
22 | Iron | Fe | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
23 | Iron | Fe | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 200 ppm |
24 | Iron | Fe | % | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 100 ppm |
25 | Potassium | K | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 200 ppm |
26 | Potassium | K | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 40 ppm |
27 | Lanthanum | La | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
28 | Lanthanum | La | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
29 | Lithium | Li | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
30 | Magnesium | Mg | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 5 ppm |
31 | Magnesium | Mg | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 200 ppm |
32 | Manganese | Mn | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
33 | Manganese | Mn | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 80 ppm |
34 | Molybdenum | Mo | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.2 ppm |
35 | Molybdenum | Mo | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
36 | Sodium | Na | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 15 ppm |
37 | Sodium | Na | mg/kg | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 200 ppm |
38 | Sodium | Na | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 100 ppm |
39 | Nickel | Ni | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 1 ppm |
40 | Nickel | Ni | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 20 ppm |
41 | Phosphorus | P | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 7 ppm |
42 | Phosphorus | P | mg/kg | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 40 ppm |
43 | Sulfur, total | TS | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 5 ppm |
44 | Scandium | Sc | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.1 ppm |
45 | Scandium | Sc | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.1 ppm |
46 | Silicon | Si | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
47 | Silicon | Si | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 0.23 % |
48 | Strontium | Sr | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
49 | Strontium | Sr | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 500 ppm |
50 | Thorium | Th | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
51 | Thorium | Th | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.2 ppm |
52 | Titanium | Ti | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
53 | Titanium | Ti | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 30 ppm |
54 | Vanadium | V | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
55 | Yttrium | Y | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
56 | Zinc | Zn | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
57 | Zinc | Zn | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 50 ppm |
58 | Aluminium oxide | Al2O3 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
59 | Calcium oxide | CaO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
60 | Iron oxide, Fe2O3 | Fe2O3 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
61 | Potassium oxide | K2O | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
62 | Magnesium oxide | MgO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
63 | Manganese oxide | MnO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
64 | Sodium oxide | Na2O | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
65 | Phosphorus pentoxide | P2O5 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
66 | Silicon dioxide | SiO2 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
67 | Titanium dioxide | TiO2 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
68 | Sum | Sum | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
69 | Arsenic | As | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
70 | Arsenic | As | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.1 ppm |
71 | Gold | Au | ng/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.002 ppm |
72 | Bromine | Br | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
73 | Cerium | Ce | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit ??? |
74 | Caesium | Cs | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
75 | Europium | Eu | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.2 ppm |
76 | Hafnium | Hf | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
77 | Lutetium | Lu | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.05 ppm |
78 | Sample mass | Samp m | g | Reimann, Clemens | | sample weight irradiated for INAA analyses |
79 | Neodymium | Nd | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit ??? |
80 | Antimony | Sb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.1 ppm |
81 | Antimony | Sb | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.01 ppm |
82 | Selenium | Se | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 3 ppm |
83 | Selenium | Se | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.01 ppm |
84 | Samarium | Sm | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.1 ppm |
85 | Tantalum | Ta | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
86 | Terbium | Tb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
87 | Uranium | U | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
88 | Tungsten | W | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
89 | Ytterbium | Yb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.2 ppm |
90 | Rubidium | Rb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 15 ppm |
91 | Fluorine | F | mg/kg | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
92 | Sulfate | [SO4]2- | % | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
93 | Silver | Ag | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.001 ppm |
94 | Bismuth | Bi | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.005 ppm |
95 | Cadmium | Cd | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.001 ppm |
96 | Lead | Pb | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.2 ppm |
97 | Tellurium | Te | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.003 ppm |
98 | Loss on ignition | LOI | % | Reimann, Clemens | Gravimetric, 1050 °C (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.1 % |
99 | pH | pH | | Reimann, Clemens | pH, combination | fraction < 2mm, detection limit 0.1 |
100 | Conductivity of soil/sediment | Cond | mS/m | Reimann, Clemens | Potentiometric | fraction < 2mm, detection limit 1 mS/m |